MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits.

Nathan McDannold1, Natalia Vykhodtseva, Scott Raymond, Ferenc A Jolesz, Kullervo Hynynen.   

Abstract

Focused ultrasound offers a method to disrupt the blood-brain barrier (BBB) noninvasively and reversibly at targeted locations. The purpose of this study was to test the safety of this method by searching for ischemia and apoptosis in areas with BBB disruption induced by pulsed ultrasound in the presence of preformed gas bubbles and by looking for delayed effects up to one month after sonication. Pulsed ultrasound exposures (sonications) were performed in the brains of 24 rabbits under monitoring by magnetic resonance imaging (MRI) (ultrasound: frequency = 1.63 MHz, burst length = 100 ms, PRF = 1 Hz, duration = 20 s, pressure amplitude 0.7 to 1.0 MPa). Before sonication, an ultrasound contrast agent (Optison, GE Healthcare, Milwaukee, WI, USA) was injected IV. BBB disruption was confirmed with contrast-enhanced MR images. Whole brain histologic examination was performed using haematoxylin and eosin staining for general histology, vanadium acid fuchsin-toluidine blue staining for ischemic neurons and TUNEL staining for apoptosis. The main effects observed were tiny regions of extravasated red blood cells scattered around the sonicated locations, indicating affected capillaries. Despite these vasculature effects, only a few cells in some of the sonicated areas showed evidence for apoptosis or ischemia. No ischemic or apoptotic regions were detected that would indicate a compromised blood supply was induced by the sonications. No delayed effects were observed either by MRI or histology up to 4 wk after sonication. Ultrasound-induced BBB disruption is possible without inducing substantial vascular damage that would result in ischemic or apoptotic death to neurons. These findings indicate that this method is safe for targeted drug delivery, at least when compared with the currently available invasive methods.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16286030     DOI: 10.1016/j.ultrasmedbio.2005.07.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  126 in total

1.  Activation of signaling pathways following localized delivery of systemically administered neurotrophic factors across the blood-brain barrier using focused ultrasound and microbubbles.

Authors:  Babak Baseri; James J Choi; Thomas Deffieux; Gesthimani Samiotaki; Yao-Sheng Tung; Oluyemi Olumolade; Scott A Small; Barclay Morrison; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2012-03-09       Impact factor: 3.609

2.  Blood-brain barrier: real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Radiology       Date:  2012-02-13       Impact factor: 11.105

Review 3.  Ultrasound enhanced drug delivery to the brain and central nervous system.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

4.  Reorganization of gap junctions after focused ultrasound blood-brain barrier opening in the rat brain.

Authors:  Angelika Alonso; Eileen Reinz; Jürgen W Jenne; Marc Fatar; Hannah Schmidt-Glenewinkel; Michael G Hennerici; Stephen Meairs
Journal:  J Cereb Blood Flow Metab       Date:  2010-03-24       Impact factor: 6.200

Review 5.  Promising approaches to circumvent the blood-brain barrier: progress, pitfalls and clinical prospects in brain cancer.

Authors:  Iason T Papademetriou; Tyrone Porter
Journal:  Ther Deliv       Date:  2015-08-25

Review 6.  Therapeutic strategies to improve drug delivery across the blood-brain barrier.

Authors:  Tej D Azad; James Pan; Ian D Connolly; Austin Remington; Christy M Wilson; Gerald A Grant
Journal:  Neurosurg Focus       Date:  2015-03       Impact factor: 4.047

7.  Multiple sessions of liposomal doxorubicin delivery via focused ultrasound mediated blood-brain barrier disruption: a safety study.

Authors:  Muna Aryal; Natalia Vykhodtseva; Yong-Zhi Zhang; Nathan McDannold
Journal:  J Control Release       Date:  2015-02-24       Impact factor: 9.776

Review 8.  Magnetic resonance-guided focused ultrasound: a new technology for clinical neurosciences.

Authors:  Ferenc A Jolesz; Nathan J McDannold
Journal:  Neurol Clin       Date:  2013-11-08       Impact factor: 3.806

9.  Clot retraction affects the extent of ultrasound-enhanced thrombolysis in an ex vivo porcine thrombosis model.

Authors:  Jonathan T Sutton; Nikolas M Ivancevich; Stephen R Perrin; Deborah C Vela; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2013-03-01       Impact factor: 2.998

Review 10.  Ultrasound-mediated blood-brain barrier disruption for targeted drug delivery in the central nervous system.

Authors:  Muna Aryal; Costas D Arvanitis; Phillip M Alexander; Nathan McDannold
Journal:  Adv Drug Deliv Rev       Date:  2014-01-22       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.