Literature DB >> 16285465

Electrical stimulation levels and electrode impedance values in children using the Med-El Combi 40+ cochlear implant: a one year follow-up.

Yael Henkin1, Ricky Kaplan-Neeman, Jona Kronenberg, Lela Migirov, Minka Hildesheimer, Chava Muchnik.   

Abstract

The present study was designed to follow changes in electrical stimulation levels and electrode impedance values (EIV) in children using the Med-El Combi 40+ cochlear implant (CI) during the first 12 months of implant use. The maps of 24 prelingually deaf children implanted at a mean age of 5.9 years (range 1-15.9 years) using the TEMPO+ speech processor programmed with CIS+ strategy were examined at five time points: initial stimulation, and 1, 3, 6, and 12 months post-initial stimulation. Most comfortable levels (M) and electrode impedance values (EIV) were analyzed according to three cochlear segments: apical, medial, and basal. Results indicated a significant increase in M levels until the 3-month time point, thereafter stabilization was evident. Furthermore, M levels in the apical segment were lower than those in the medial and basal segments. EIV decreased from initial stimulation to the 3-month time point and was then stable through the study follow up. Interestingly, the finding of higher EIV in the apical segment may be attributed to the physical characteristics of the Med-El electrode. In conclusion, the pattern of stabilization of M levels found in the present study is similar to that reported for children using other devices. The data presented here may be useful as a guideline for programming M levels and monitoring EIV in infants and young children. They may further help clinicians to identify those children that fall outside the 'typical' range.

Entities:  

Mesh:

Year:  2005        PMID: 16285465     DOI: 10.1515/jbcpp.2005.16.2-3.127

Source DB:  PubMed          Journal:  J Basic Clin Physiol Pharmacol        ISSN: 0792-6855


  3 in total

1.  Design, Fabrication, and Evaluation of a Parylene Thin-Film Electrode Array for Cochlear Implants.

Authors:  Yuchen Xu; Chuan Luo; Fan-Gang Zeng; John C Middlebrooks; Harrison W Lin; Zheng You
Journal:  IEEE Trans Biomed Eng       Date:  2018-07-10       Impact factor: 4.538

2.  Longitudinal variations in fitting parameters for adult cochlear implant recipients.

Authors:  F Mosca; R Grassia; C A Leone
Journal:  Acta Otorhinolaryngol Ital       Date:  2014-04       Impact factor: 2.124

3.  Temporal changes in impedance of implanted adults for various cochlear segments.

Authors:  C A Leone; F Mosca; R Grassia
Journal:  Acta Otorhinolaryngol Ital       Date:  2017-08       Impact factor: 2.124