Literature DB >> 16285403

Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms.

Lisheng Xu1, David Zhang, Kuanquan Wang.   

Abstract

This paper presents an energy ratio-based method and a wavelet-based cascaded adaptive filter (CAF) for detecting and removing baseline drift from pulse waveforms. Experiments on 50 simulated and five hundred real pulse signals demonstrate that this CAF outperforms traditional filters both in removing baseline drift and in preserving the diagnostic information of pulse waveforms.

Mesh:

Year:  2005        PMID: 16285403     DOI: 10.1109/TBME.2005.856296

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Computerized wrist pulse signal diagnosis using modified auto-regressive models.

Authors:  Yinghui Chen; Lei Zhang; David Zhang; Dongyu Zhang
Journal:  J Med Syst       Date:  2009-09-10       Impact factor: 4.460

2.  Novel diagnostic model for the deficient and excess pulse qualities.

Authors:  Jaeuk U Kim; Young Ju Jeon; Young-Min Kim; Hae Jung Lee; Jong Yeol Kim
Journal:  Evid Based Complement Alternat Med       Date:  2011-09-05       Impact factor: 2.629

3.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

4.  Refined Multiscale Entropy Analysis of Wrist Pulse for Gender Difference in Traditional Chinese Medicine among Young Individuals.

Authors:  Huaxing Xu; Qia Wang; Xiaobo Mao; Zhigang Shang; Yuping Zhao; Luqi Huang
Journal:  Evid Based Complement Alternat Med       Date:  2022-02-08       Impact factor: 2.629

5.  New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.

Authors:  Jang-Han Bae; Young Ju Jeon; Jong Yeol Kim; Jaeuk U Kim
Journal:  Evid Based Complement Alternat Med       Date:  2013-09-26       Impact factor: 2.629

6.  Pulse waveform classification using support vector machine with Gaussian time warp edit distance kernel.

Authors:  Danbing Jia; Dongyu Zhang; Naimin Li
Journal:  Comput Math Methods Med       Date:  2014-02-09       Impact factor: 2.238

7.  Improving the accuracy and robustness of carotid-femoral pulse wave velocity measurement using a simplified tube-load model.

Authors:  Lisheng Xu; Shuran Zhou; Lu Wang; Yang Yao; Liling Hao; Lin Qi; Yudong Yao; Hongguang Han; Ramakrishna Mukkamala; Stephen E Greenwald
Journal:  Sci Rep       Date:  2022-03-25       Impact factor: 4.996

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.