Literature DB >> 16279822

Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions.

Chung-Chen Jane Yao1, Jang-Jaer Lee, Hsing-Yu Chen, Zwei-Chieng Jenny Chang, Hsin-Fu Chang, Yi-Jane Chen.   

Abstract

The intrusion of an overerupted maxillary molar using traditional orthodontic treatment is a real challenge. The aim of this study was to investigate the envelope of intrusive movements of a maxillary molar in cases using mini-implants as anchorage with partial or full-mouth fixed edgewise appliances. The cusp tips of the pretreatment and postintrusion dental casts were recorded by a three-dimensional (3D) digitizer. The 3D data of the serial dental casts were analyzed to distinguish the direction and magnitude of individual tooth movement. The mean intrusive movement of the maxillary first molars was three to four mm, with a maximum of over eight mm. For the adjacent maxillary second molars and second premolars, the amount of intrusion was two mm and 1-2 mm, respectively. This study demonstrated that significant true intrusion of maxillary molars could be obtained in a well-controlled manner by using fixed appliances with titanium mini-implants as bony anchorage.

Entities:  

Mesh:

Year:  2005        PMID: 16279822     DOI: 10.1043/0003-3219(2005)75[754:MMIWFA]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  14 in total

1.  Intrusion of overerupted maxillary molars with miniscrew implant anchorage: a radiographic evaluation.

Authors:  Chun-Lei Xun; Hong Zhao; Xiang-Long Zeng; Xing Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-10-20

2.  Microanchor mediated upper molar intrusion in deep posterior bite after long-term edentulousness for prosthetic reconstruction with dental implants.

Authors:  Constantin A Landes; Bettina Glasl; Stefan Kopp; Robert Sader; Björn Ludwig
Journal:  Oral Maxillofac Surg       Date:  2008-09

3.  Efficiency of two protocols for maxillary molar intrusion with mini-implants.

Authors:  Juliana Volpato Curi Paccini; Flávio Augusto Cotrim-Ferreira; Flávio Vellini Ferreira; Karina Maria Salvatore de Freitas; Rodrigo Hermont Cançado; Fabrício Pinelli Valarelli
Journal:  Dental Press J Orthod       Date:  2016-06

4.  The effect of social media on patient acceptance of temporary anchorage devices.

Authors:  Ariane Sampson; Daniel S F Figueiredo; Huw G Jeremiah; Dauro D Oliveira; Laize R P Freitas; Michele Chahoud; Rodrigo V Soares; Martyn T Cobourne
Journal:  Angle Orthod       Date:  2021-05-01       Impact factor: 2.079

5.  Use of mini-implants to avoid maxillary surgery for Class III mandibular prognathic patient: a long-term post-retention case.

Authors:  Hee-Yeon Suh; Shin-Jae Lee; Heung Sik Park
Journal:  Korean J Orthod       Date:  2014-11-24       Impact factor: 1.372

Review 6.  Risk factors associated with the stability of mini-implants and mini-plates: systematic review and meta-analysis.

Authors:  Paola Marques de Mattos; Flavio Magno Gonçalves; Isabela Bittencourt Basso; Bianca Simone Zeigelboim; Marcio Furtado Niwa; José Stechman-Neto; Rosane Sampaio Santos; Cristiano Miranda de Araujo; Odilon Guariza-Filho
Journal:  Clin Oral Investig       Date:  2021-10-21       Impact factor: 3.573

Review 7.  Intrusion of Maxillary Posterior Teeth by Skeletal Anchorage: A Systematic Review and Case Report with Thin Alveolar Biotype.

Authors:  Avram Manea; Cristian Dinu; Mihaela Băciuţ; Smaranda Buduru; Oana Almășan
Journal:  J Clin Med       Date:  2022-06-30       Impact factor: 4.964

8.  Force magnitude as a variable in maxillary buccal segment intrusion in adult patients with skeletal open bite.

Authors:  Heba E Akl; Amr M Abouelezz; Fouad A El Sharaby; Amr R El-Beialy; Mohamed Abd El-Ghafour
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

9.  Mini-implants in the anchorage armamentarium: new paradigms in the orthodontics.

Authors:  Masaru Yamaguchi; Toshihiro Inami; Ko Ito; Kazutaka Kasai; Yasuhiro Tanimoto
Journal:  Int J Biomater       Date:  2012-06-05

10.  Volumetric measurement of root resorption following molar mini-screw implant intrusion using cone beam computed tomography.

Authors:  Wen Li; Fei Chen; Feng Zhang; Wanghui Ding; Qingsong Ye; Jiejun Shi; Baiping Fu
Journal:  PLoS One       Date:  2013-04-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.