Literature DB >> 16279074

MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies.

A K Jones1, F D Pazik, D E Hintenlang, W E Bolch.   

Abstract

The objective of the present study was to explore the use of the TN-1002RD metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter for measuring tissue depth dose at diagnostic photon energies in both homogeneous and heterogeneous tissue-equivalent materials. Three cylindrical phantoms were constructed and utilized as a prelude to more complex measurements within tomographic physical phantoms of pediatric patients. Each cylindrical phantom was constructed as a stack of seven 5-cm-diameter and 1-cm-thick discs of materials radiographically representative of either soft tissue (S), bone (B), or lung tissue (L) at diagnostic photon energies. In addition to a homogeneous phantom of soft tissue (SSSSSSS), two heterogeneous phantoms were constructed: SSBBSSS and SBLLBSS. MOSFET dosimeters were then positioned at the interface of each disc, and the phantoms were then irradiated at 66 kVp and 200 mAs. Measured values of absorbed dose at depth were then compared to predicated values of point tissue dose as determined via Monte Carlo radiation transport modeling. At depths exceeding 2 cm, experimental results matched the computed values of dose with high accuracy regardless of the dosimeter orientation (epoxy bubble facing toward or away from the x-ray beam). Discrepancies were noted, however, between measured and calculated point doses near the surface of the phantom (surface to 2 cm depth) when the dosimeters were oriented with the epoxy bubble facing the x-ray beam. These discrepancies were largely eliminated when the dosimeters were placed with the flat side facing the x-ray beam. It is therefore recommended that the MOSFET dosimeters be oriented with their flat sides facing the beam when they are used at shallow depths or on the surface of either phantoms or patients.

Entities:  

Mesh:

Year:  2005        PMID: 16279074     DOI: 10.1118/1.2047827

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans.

Authors:  Da Zhang; Atul Padole; Xinhua Li; Sarabjeet Singh; Ranish Deedar Ali Khawaja; Diego Lira; Tianyu Liu; Jim Q Shi; Alexi Otrakji; Mannudeep K Kalra; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

2.  Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

Authors:  Sigal Trattner; Bin Cheng; Radoslaw L Pieniazek; Udo Hoffmann; Pamela S Douglas; Andrew J Einstein
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

3.  Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

Authors:  Sigal Trattner; Anjali Chelliah; Peter Prinsen; Carrie B Ruzal-Shapiro; Yanping Xu; Sachin Jambawalikar; Maxwell Amurao; Andrew J Einstein
Journal:  AJR Am J Roentgenol       Date:  2017-01-17       Impact factor: 3.959

4.  Effective dose estimation for pediatric upper gastrointestinal examinations using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology.

Authors:  Brent Emigh; Christopher L Gordon; Bairbre L Connolly; Michelle Falkiner; Karen E Thomas
Journal:  Pediatr Radiol       Date:  2013-03-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.