Monte Carlo modeling of the response of NRC's 90Sr/90Y primary beta standard.

T Palani Selvam1, P R B Saull, D W O Rogers.   

Abstract

The BEAMnrc/EGSnrc Monte Carlo code system is employed to develop a model of the National Research Council of Canada primary standard of absorbed dose to tissue in a beta radiation field, comprising an extrapolation chamber and 90Sr/90Y beta source. We benchmark the model against the measured response of the chamber in terms of absorbed dose to air, for three different experimental setups when irradiated by the 90Sr/90Y source. For the first setup, the chamber cavity depth is fixed at 0.2 cm and the source-to-chamber distance varied between 11 and 60 cm. In the other two cases, the source-to-chamber distance is fixed at 30 cm. In one case the response for different chamber depths is studied, while in the other case the chamber depth is fixed at 0.2 cm as different thicknesses of Mylar are added to the front surface of the extrapolation chamber. The agreement as a function of distance between the calculated and measured responses is within 0.37% for a variation in response of a factor of 29. In the case of dose versus chamber depth, the agreement is within 0.4% for the ISO-recommended nominal depths of 0.025-0.25 cm. Agreement between calculated and measured responses is very good (between 0.02% and 0.2%) for added Mylar foils of thicknesses up to 10.8 mg cm(-2). For larger Mylar thicknesses, deviations of 0.6%-1.2% are observed, which are possibly due to the systematic uncertainties associated with the restricted collisional stopping powers of air or Mylar used in the calculations. We conclude that our simulation model represents the extrapolation chamber and 90Sr/90Y source with adequate accuracy to calculate correction factors for accurate realization of dose rate to tissue at a depth of 7 mg cm(-2) in an ICRU tissue phantom, despite the fact that the uncertainties in the physical characteristics of the source leave some uncertainty in certain calculated quantities.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16279060     DOI: 10.1118/1.1997347

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  1 in total

1.  Monte Carlo-based Spencer-Attix and Bragg-Gray tissue-to-air stopping power ratios for ISO beta sources.

Authors:  T Palani Selvam; S Vandana; A K Bakshi; D A R Babu
Journal:  Radiat Prot Dosimetry       Date:  2015-05-09       Impact factor: 0.972

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.