Literature DB >> 16278633

Factors associated with mortality and long time survival in patients undergoing modified Bentall operations.

T Schachner1, K Vertacnik, J Nagiller, G Laufer, J Bonatti.   

Abstract

AIM: We report our results on mortality, morbidity and long time events after composite graft replacement of the aortic root and ascending aorta/aortic arch and factors associated with them.
METHODS: Seventy-four patients, aged 52 years (15-73) underwent modified ''button'' Bentall operation. The indication for operation was acute dissection in 29 (39%) patients, chronic dissection in 3 (4%), aortic regurgitation after previous replacement of the ascending aorta because of aortic dissection in 2 (3%) and non dissecting aneurysm in 40 (54%). Concommitant procedures were (partial) replacement of the aortic arch in 11 (15%) and coronary artery bypass grafting in 5 (7%). Six patients (8%) had undergone previous cardiac surgery. Mean follow up was for 49 +/- 46 months (maximum 198).
RESULTS: Length of intensive care unit (ICU) stay was 3 days (1-72). Hospital mortality was 12%. Factors significantly associated with hospital mortality were: aortic dissection, cardiopulmonary bypass time, aortic cross clamp time, deep hypothermic circulatory arrest, low cardiac output syndrome, revision due to bleeding, renal failure requiring hemofiltration, multisystemic organ failure and sepsis. None of these factors was significantly associated with long term survival. Survival rates including hospital deaths were 86%, 84%, 75% and 75% after 1, 3, 5 and 7 years respectively. Pseudoaneurysm at the composite graft occurred in 3%, infection of the prosthesis in 1%. Neither valve thrombosis nor thromboembolic events occurred postoperatively.
CONCLUSIONS: Modified Bentall operation is a demanding operation with acceptable hospital mortality. The long time survival rates are good and the big majority of patients is eventfree after operation.

Entities:  

Mesh:

Year:  2005        PMID: 16278633

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  4 in total

1.  Thromboelastometry Based Early Goal-Directed Coagulation Management Reduces Blood Transfusion Requirements, Adverse Events, and Costs in Acute Type A Aortic Dissection: A Pilot Study.

Authors:  Alexander A Hanke; Ulf Herold; Daniel Dirkmann; Konstantinos Tsagakis; Heinz Jakob; Klaus Görlinger
Journal:  Transfus Med Hemother       Date:  2012-03-15       Impact factor: 3.747

2.  Eighteen years of clinical experience with a modification of the Bentall button technique for total root replacement.

Authors:  Dimos Karangelis; Dimitrios Tzertzemelis; Alexandros A Demis; Stella Economidou; Matthew Panagiotou
Journal:  J Thorac Dis       Date:  2018-12       Impact factor: 2.895

3.  The evidence in a Bentall procedure with Valsalva graft: is this standard of care?

Authors:  Ziv Beckerman; Bradley G Leshnower; LaRonica McPherson; Jose N Binongo; Yi Lasanajak; Edward P Chen
Journal:  J Vis Surg       Date:  2018-05-10

4.  Blood groups and acute aortic dissection type III.

Authors:  Nikola Fatic; Aleksandar Nikolic; Mihailo Vukmirovic; Nemanja Radojevic; Nenad Zornic; Igor Banzic; Nikola Ilic; Dusan Kostic; Bogdan Pajovic
Journal:  Arch Med Sci       Date:  2016-05-05       Impact factor: 3.318

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.