Literature DB >> 1627730

Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry.

C G Fraser1, P H Petersen, C Ricos, R Haeckel.   

Abstract

A Working Group of the European Group for the Evaluation of Reagents and Analytical Systems in Laboratory Medicine proposes, after detailed study of the advantages and disadvantages of available strategies, the following quality specifications for analytical systems for clinical chemistry. Total imprecision should be: (a) less than one-half of the average within-subject biological variation, or (b) less than the state of the art achieved by the best 0.20 fractile of laboratories, whichever is the less stringent. The second approach may be used when data on biological variation do not exist. Inaccuracy should be: (a) less than one-quarter of the group (within- plus between-subject) biological variation, or (b) less than one-sixteenth of the reference interval, when data on group biological variation do not exist, or (c) less than twice the ideal imprecision, if the above specifications are too demanding.

Mesh:

Year:  1992        PMID: 1627730

Source DB:  PubMed          Journal:  Eur J Clin Chem Clin Biochem        ISSN: 0939-4974


  12 in total

1.  Analytical quality--what should we be aiming for?

Authors:  Ken Sikaris
Journal:  Clin Biochem Rev       Date:  2008-08

2.  Quality leadership and quality control.

Authors:  Tony Badrick
Journal:  Clin Biochem Rev       Date:  2003-08

3.  Evaluation of imprecision, bias and total error of clinical chemistry analysers.

Authors:  S S Biswas; M Bindra; V Jain; P Gokhale
Journal:  Indian J Clin Biochem       Date:  2014-06-22

4.  The long-term biological variability of fasting plasma glucose and serum fructosamine in healthy Beagle dogs.

Authors:  A L Jensen; H Aaes; L Iversen; T K Petersen
Journal:  Vet Res Commun       Date:  1999-03       Impact factor: 2.459

5.  Feasibility of measuring sodium, potassium and creatinine from urine sample on dried filter paper.

Authors:  Mohamad Tarik; Lakshmy Ramakrishnan; Ritvik Amarchand; Harshal Ramesh Salve; Prashant Mathur; Pradeep Joshi; Anand Krishnan
Journal:  Bioanalysis       Date:  2019-04-17       Impact factor: 2.681

6.  Stability of 35 biochemical and immunological routine tests after 10 hours storage and transport of human whole blood at 21°C.

Authors:  Linda O Henriksen; Nina R Faber; Mette F Moller; Ebba Nexo; Annebirthe B Hansen
Journal:  Scand J Clin Lab Invest       Date:  2014-07-02       Impact factor: 1.713

7.  Rapid assessment of iron in blood plasma and serum by spectrophotometry with cloud-point extraction.

Authors:  Tatyana Samarina; Mikhail Proskurnin
Journal:  F1000Res       Date:  2015-08-25

8.  Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples.

Authors:  Ransi Ann Abraham; Praween K Agrawal; Rajib Acharya; Avina Sarna; Sowmya Ramesh; Robert Johnston; Arjan de Wagt; Nizamuddin Khan; Akash Porwal; Sucheta Banerjee Kurundkar; Arvind Pandey; Raghu Pullakhandam; Krishnapillai Madhavan Nair; Geeta Trilok Kumar; H P S Sachdev; Umesh Kapil; Renu Saxena; Sila Deb; Ajay Khera; Lakshmy Ramakrishnan
Journal:  Biochem Med (Zagreb)       Date:  2019-06-15       Impact factor: 2.313

9.  Use of a blood gas analyzer and a laboratory autoanalyzer in routine practice to measure electrolytes in intensive care unit patients.

Authors:  Yasemin U Budak; Kagan Huysal; Murat Polat
Journal:  BMC Anesthesiol       Date:  2012-08-03       Impact factor: 2.217

10.  Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA.

Authors:  Paolo Mocarelli; Gary L Horowitz; Pier Mario Gerthoux; Rossana Cecere; Roland Imdahl; Janneke Ruinemans-Koerts; Hilmar Luthe; Silvia Pesudo Calatayud; Marie Luisa Salve; Albert Kunst; Margaret McGovern; Katherine Ng; Wolfgang Stockmann
Journal:  J Autom Methods Manag Chem       Date:  2008
View more