Literature DB >> 16275303

Effect of soldering on the metal-ceramic bond strength of an Ni-Cr base alloy.

Ioannis Nikellis1, Anna Levi, Spiros Zinelis.   

Abstract

STATEMENT OF PROBLEM: Although soldering is a common laboratory procedure, the use of soldering alloys may adversely affect metal-ceramic bond strength and potentially decrease the longevity of metal-ceramic restorations.
PURPOSE: The purpose of this study was to investigate the effect of soldering on metal-ceramic bond strength of a representative Ni-Cr base metal alloy.
MATERIAL AND METHODS: Twenty-eight rectangular (25 x 3 x 0.5 mm) Ni-based alloy (Wiron 99) specimens were equally divided into soldering (S) and reference (R) groups. Soldering group specimens were covered with a 0.1-mm layer of the appropriate solder (Wiron-Lot) and reduced by 0.1 mm on the opposite side. Five specimens of each group were used for the measurement of surface roughness parameter (R(z)) and hardness, and 3 were used for measurement of the modulus of elasticity. Six specimens of each group were covered with porcelain (Ceramco 3) and subjected to a 3-point bending test for evaluation of the metal-ceramic bond strength according to the ISO 9693 specification. The data from surface roughness, hardness, modulus of elasticity, and metal-ceramic bond strength were analyzed statistically, using independent t tests (alpha=.05).
RESULTS: Statistical analysis of the R(z) surface roughness parameter (S: 3.4 +/- 0.3 mum; R: 3.7 +/- 0.7 microm; P=.07) and bond strength (S: 46 +/- 3 MPa; R: 40 +/- 5 MPa; P=.057) failed to reveal any significant difference between the 2 groups. The specimens of the soldering group demonstrated significantly lower values both in hardness (S: 128 +/- 11 VHN; R: 217 +/- 4 VHN; P<.001) and in modulus of elasticity (S: 135 +/- 4 GPa; R: 183 +/- 6 GPa; P=.035) than the reference group.
CONCLUSION: Under the conditions of the present study, the addition of solder to the base metal alloy did not affect the metal-ceramic bond strength.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16275303     DOI: 10.1016/j.prosdent.2005.09.012

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint.

Authors:  Sang-Yeob Lee; Jong-Hyuk Lee
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

2.  The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy.

Authors:  Mitra Farzin; Rashin Giti; Amin Asalforush-Rezaiye
Journal:  Materials (Basel)       Date:  2018-03-22       Impact factor: 3.623

3.  The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

Authors:  Farnaz Fattahi; Zahra Hashemi Ardakani; Maryam Hashemi Ardakani
Journal:  J Dent (Shiraz)       Date:  2015-12

4.  Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures.

Authors:  Fariborz Vafaee; Farnaz Firouz; Masoumeh Khoshhal; Amirarsalan Hooshyarfard; Armaghan Shahbazi; Ghodratollah Roshanaei
Journal:  J Dent (Tehran)       Date:  2017-05

5.  Comparative Analysis of Mechanical Properties and Metal-Ceramic Bond Strength of Co-Cr Dental Alloy Fabricated by Different Manufacturing Processes.

Authors:  Xingting Han; Tomofumi Sawada; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer; Frank Rupp; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2018-09-22       Impact factor: 3.623

  5 in total