Literature DB >> 16274906

Rotation sequence as an important factor in shoulder kinematics.

Miroslav Senk1, Laurence Chèze.   

Abstract

BACKGROUND: The International Society of Biomechanics has proposed a standardization recommendation for motion recordings of the upper extremity defining the set of bony landmarks, local coordinate systems and joint coordinate systems. The aim of our study was to verify the clinical interpretation of the proposed rotation sequence for the glenohumeral joint and to compare it with other sequences.
METHODS: Fifteen glenohumeral movements in their maximal ranges were tested on five healthy subjects. The movements were separated into five groups (flexion, extension, abduction, horizontal flexion and circumduction) with three humeral rotation positions (full external, full internal and neutral). Four glenohumeral rotation sequences were constructed using YXY, YXZ, ZXY and XZY orders and angle amplitudes were examined in terms of gimbal lock and amplitude coherence.
FINDINGS: The results of the gimbal lock incidence and amplitude coherence should be taken into account together. Therefore, the suitable rotation sequences for all rotation variations of abduction and extension were found and no tested rotation sequence was found to be clinically interpretable for all tested movements.
INTERPRETATION: Before glenohumeral three-dimension experiments the choice of the rotation sequence should be made in agreement with the no-gimbal lock incidence and amplitude interpretability of the performed movements.

Entities:  

Mesh:

Year:  2005        PMID: 16274906     DOI: 10.1016/j.clinbiomech.2005.09.007

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  17 in total

1.  Comparison of glenohumeral motion using different rotation sequences.

Authors:  Vandana Phadke; Jonathan P Braman; Robert F LaPrade; Paula M Ludewig
Journal:  J Biomech       Date:  2010-12-24       Impact factor: 2.712

2.  Upper limb motion analysis in children with hemiplegic cerebral palsy: proximal kinematic changes after distal botulinum toxin or surgical treatments.

Authors:  Frank Fitoussi; Amadou Diop; Nathalie Maurel; El Mostefa Laasel; Brice Ilharreborde; Georges François Penneçot
Journal:  J Child Orthop       Date:  2011-09-03       Impact factor: 1.548

3.  The Influence of Sex on Upper Extremity Joint Dynamics in Pediatric Manual Wheelchair Users With Spinal Cord Injury.

Authors:  Matthew M Hanks; Joshua M Leonardis; Alyssa J Schnorenberg; Joseph J Krzak; Adam Graf; Lawrence C Vogel; Gerald F Harris; Brooke A Slavens
Journal:  Top Spinal Cord Inj Rehabil       Date:  2021-08-13

4.  Statistical Quantification of the Effects of Marker Misplacement and Soft-Tissue Artifact on Shoulder Kinematics and Kinetics.

Authors:  Maxence Lavaill; Saulo Martelli; Graham K Kerr; Peter Pivonka
Journal:  Life (Basel)       Date:  2022-05-31

5.  Manual wheelchair biomechanics while overcoming various environmental barriers: A systematic review.

Authors:  Théo Rouvier; Aude Louessard; Emeline Simonetti; Samuel Hybois; Joseph Bascou; Charles Pontonnier; Hélène Pillet; Christophe Sauret
Journal:  PLoS One       Date:  2022-06-23       Impact factor: 3.752

6.  Influence of the side of brain damage on postural upper-limb control including the scapula in stroke patients.

Authors:  Johanna V G Robertson; Nicolas Roche; Agnès Roby-Brami
Journal:  Exp Brain Res       Date:  2012-02-14       Impact factor: 1.972

7.  3D kinematics of the glenohumeral joint during abduction motion: an ex vivo study.

Authors:  F Billuart; L Devun; O Gagey; W Skalli; D Mitton
Journal:  Surg Radiol Anat       Date:  2007-04-26       Impact factor: 1.354

8.  Influence of pain location and hand dominance on scapular kinematics and EMG activities: an exploratory study.

Authors:  Yi-Fen Shih; Yi-Hsuan Kao
Journal:  BMC Musculoskelet Disord       Date:  2011-11-24       Impact factor: 2.362

9.  Trunk and shoulder kinematic and kinetic and electromyographic adaptations to slope increase during motorized treadmill propulsion among manual wheelchair users with a spinal cord injury.

Authors:  Dany Gagnon; Annie-Claude Babineau; Audrey Champagne; Guillaume Desroches; Rachid Aissaoui
Journal:  Biomed Res Int       Date:  2015-02-22       Impact factor: 3.411

10.  Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations.

Authors:  Brice Bouvier; Sonia Duprey; Laurent Claudon; Raphaël Dumas; Adriana Savescu
Journal:  Sensors (Basel)       Date:  2015-07-31       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.