Literature DB >> 16274891

Concordance of mammographic classifications of microcalcifications in breast cancer diagnosis: Utility of the Breast Imaging Reporting and Data System (fourth edition).

Z Sumru Coşar1, Meltem Cetin, Tuba Kizil Tepe, Recep Cetin, Aliye C Zarali.   

Abstract

The purpose of this study is to evaluate breast microcalcifications according to morphology, distribution, level of suspicion, Breast Imaging Reporting and Data System (BI-RADS; fourth edition) final assessment, and recommendation categories and to assess positive predictive values and interobserver variability among three observers in 83 patients in whom biopsies had been performed. Although there is considerable inconsistencies in agreement between observers in the classification of microcalcifications, the usage of BI-RADS (fourth edition), in which the explicit recommendations for the description of the lesions was made, succeeds in the evaluation of microcalcifications.

Entities:  

Mesh:

Year:  2005        PMID: 16274891     DOI: 10.1016/j.clinimag.2005.05.002

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  4 in total

1.  Observer Variability of the Breast Imaging Reporting and Data System (BI-RADS) Lexicon for Mammography.

Authors:  Zehra H Adibelli; Ruken Ergenc; Ozgur Oztekin; Suheyla Ecevit; Gokhan Unal; Yusuf Abal
Journal:  Breast Care (Basel)       Date:  2010-02-16       Impact factor: 2.860

2.  Mammotome(®) and EnCor (®): comparison of two systems for stereotactic vacuum-assisted core biopsy in the characterisation of suspicious mammographic microcalcifications alone.

Authors:  Giovanna Mariscotti; Manuela Durando; Mattia Robella; Francesca Angelino; Elisa Regini; Pier Paolo Campanino; Marco Belletti; Silvia Osano; Laura Bergamasco; Paolo Fonio; Giovanni Gandini
Journal:  Radiol Med       Date:  2014-08-15       Impact factor: 3.469

3.  Can positron emission mammography help to identify clinically significant breast cancer in women with suspicious calcifications on mammography?

Authors:  Almir G V Bitencourt; Eduardo N P Lima; Bruna R C Macedo; Jorge L F A Conrado; Elvira F Marques; Rubens Chojniak
Journal:  Eur Radiol       Date:  2016-09-02       Impact factor: 5.315

Review 4.  Predictors of interobserver agreement in breast imaging using the Breast Imaging Reporting and Data System.

Authors:  Anna Liza M Antonio; Catherine M Crespi
Journal:  Breast Cancer Res Treat       Date:  2010-02-21       Impact factor: 4.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.