Literature DB >> 16274023

Transesophageal echocardiographic follow-up of pulmonary veins in patients undergoing ostial radiofrequency catheter ablation for atrial fibrillation.

Elisabetta Artuso1, Berardino Stomaci, Roberto Verlato, Pietro Turrini, Nicolò Lafisca, Maria Stella Baccillieri, Attilio Di Marco, Piergiuseppe Piovesana.   

Abstract

BACKGROUND: Ostial radiofrequency catheter ablation (RFCA) of pulmonary veins (PVs) is a promising invasive approach for the non-pharmacologic treatment of atrial fibrillation, but PV stenosis has been reported as a possible complication of this intervention. The aim of this study was to assess PV anatomy and stenosis (i.e. number and progression) by means of transesophageal echocardiography (TEE) during the follow-up of patients undergoing RFCA.
METHODS: Twenty-three consecutive patients with refractory and highly symptomatic atrial fibrillation underwent ostial radiofrequency isolation of arrhythmogenic triggers/foci, localized into the PVs, by an electroanatomic approach (CARTO system) or circular mapping with a multipolar catheter (LASSO) placed under radioscopic guidance. All patients were investigated using TEE and magnetic resonance angiography before radiofrequency application to evaluate PV anatomy. TEE examination was repeated after 2 months of follow-up and, in the presence of a stenosis, 1 year later.
RESULTS: TEE allowed to identify 100% of the left and right superior PVs, 96% of right inferior PVs, and 74% of the left inferior PVs. Anatomic variants were detected at TEE in 33% of patients against 37% at magnetic resonance angiography (95% of concordance). After ostial RFCA, TEE disclosed a significant reduction in the mean diameters of the left superior PV (14.1 +/- 3.2 vs 12.0 +/- 2.7 mm, p < 0.01), left inferior PV (11.2 +/- 2.3 vs 9.8 +/- 2.2 mm, p = 0.05) and right superior PV (14.2 +/- 2.6 vs 12.9 +/- 2.7 mm, p < 0.05), and an increase in the mean peak velocities of the left superior PV (69.8 +/- 14.8 vs 91 +/- 42.4 cm/s, p < 0.05) and left inferior PV (59.2 +/- 18.1 vs 79.3 +/- 40.5 cm/s, p < 0.05). From a total of 88 PVs treated, 7 (7.9%) showed a higher significant stenosis in patients treated using the LASSO than the CARTO system (31.3 vs 2.8% respectively, p < 0.01). After 1-year follow-up there was no progression of PV stenosis.
CONCLUSIONS: TEE was successful to evaluate PV anatomy and stenosis of patients undergoing ostial RFCA for atrial fibrillation. This complication is not rare and seems to be strictly related to the method of ablation, in particular when circular mapping and disconnection of triggers/foci was carried out by only a circular multipolar catheter without an electroanatomic approach.

Entities:  

Mesh:

Year:  2005        PMID: 16274023

Source DB:  PubMed          Journal:  Ital Heart J        ISSN: 1129-471X


  3 in total

1.  CASE 7--2014 Rescue therapy with early extracorporeal membrane oxygenation for primary graft dysfunction after bilateral lung transplantation.

Authors:  Ali M Farooki; Heidi Bazick-Cuschieri; Emily K Gordon; James C Lee; Edward C Cantu; John G Augoustides
Journal:  J Cardiothorac Vasc Anesth       Date:  2013-08-30       Impact factor: 2.628

2.  Pulmonary Vein Remodeling Following Atrial Fibrillation Ablation: Implications For The Radiographic Diagnosis Of Pulmonary Vein Stenosis.

Authors:  Faisal M Merchant; Mathew R Levy; Shahriar Iravanian; Ramal M Weragoda; Edward C Clermont; Heval M Kelli; Robert L Eisner; David Vadnais; Mikhael F El-Chami; Angel R Leon; David B Delurgio
Journal:  J Atr Fibrillation       Date:  2016-08-31

3.  Transesophageal echocardiography: a follow-up tool after catheter ablation of atrial fibrillation and interventional therapy of pulmonary vein stenosis and occlusion.

Authors:  Carsten Schneider; Sabine Ernst; Rainer Malisius; Edda Bahlmann; Friedrun Lampe; Thomas Broemel; Korff Krause; Sigrid Boczor; Matthias Antz; Karl-Heinz Kuck
Journal:  J Interv Card Electrophysiol       Date:  2007-04-26       Impact factor: 1.759