Literature DB >> 16273910

Evaluation of intra- and interobserver reliability and image reproducibility to assess usefulness of high-resolution ultrasonography for measurement of anterior segment structures of canine eyes.

Ellison Bentley1, Paul E Miller, Kathryn A Diehl.   

Abstract

OBJECTIVE: To evaluate the usefulness of high-resolution ultrasonography (HRUS) for measurements of anterior segment structures in canine eyes. ANIMALS: 4 clinically normal Beagles. PROCEDURE: Images were obtained from 8 eyes with a handheld 20-MHz transducer. Eleven anterior segment structures on each image were measured 5 times by 2 independent observers. Coefficients of variation (CVs) for measurements were used to assess intraobserver reliability. Interobserver reliability was assessed by comparing measurements obtained by the 2 observers from the same images. Five images were sequentially obtained from 2 locations (ie, superior and temporal) to evaluate image reproducibility. Anterior segment structures were measured once on each image; image reproducibility was assessed by use of the CV for each parameter measured. Imaging location was assessed by comparison of CV for measurements from each location.
RESULTS: CVs were < 10% for observer A for all measurements except the ciliary cleft area (11.63%). The CVs were > 10% for observer B for measurements of the angle recess area (18.51%) and ciliary cleft width (17.44%) and area (16.01%). Significant differences in measurements between observers were found for 5 of 11 anterior segment structures. Imaging the superior aspect of the globe provided the most reproducible images, although image reproducibility was still somewhat variable, with the highest and lowest CVs for measurements of 33.01% and 11.32%, respectively, in the superior position. CONCLUSIONS AND CLINICAL RELEVANCE: High-resolution ultrasound images can be used to reliably measure various anterior segment structures. Clinically relevant findings in the anterior segment of canine eyes may be detectable by use of HRUS.

Entities:  

Mesh:

Year:  2005        PMID: 16273910     DOI: 10.2460/ajvr.2005.66.1775

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

1.  Effect of topical latanoprost 0.005% on intraocular pressure and pupil diameter in normal and glaucomatous cats.

Authors:  Jessica E McDonald; Julie A Kiland; Paul L Kaufman; Ellison Bentley; N Matthew Ellinwood; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2015-07-16       Impact factor: 1.644

2.  Effects of unilateral topical administration of 0.5% tropicamide on anterior segment morphology and intraocular pressure in normal cats and cats with primary congenital glaucoma.

Authors:  Filipe Espinheira Gomes; Ellison Bentley; Ting-Li Lin; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2011-09       Impact factor: 1.644

3.  Ultrasound biomicroscopic findings of the iridocorneal angle in live healthy and glaucomatous dogs.

Authors:  Takashi Hasegawa; Manabu Kawata; Mitsuharu Ota
Journal:  J Vet Med Sci       Date:  2015-07-24       Impact factor: 1.267

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.