Literature DB >> 16271367

Oxygen consumption, pCO2 gradients and regional blood flow distribution in an alternative model of intestinal autotransplantation.

Ruy J Cruz1, Cristiano J Correia, Cristiane M F Ribeiro, Luiz F Poli de Figueiredo, Mauricio Rocha e Silva.   

Abstract

BACKGROUND: Postoperative complications after intestinal transplantation can be attributed to hypothermic storage and reperfusion injury. Our objective was to evaluate, in an alternative model of intestinal autotransplantation, the initial effects of isolated intestinal hypothermic perfusion (at 4 degrees C, IHP) on mucosal and serosal blood flow distribution and correlate these findings with other systemic and regional markers of mesenteric ischemia. In addition, we sought to obtain evidence that intestinal pCO2 measurement can be a useful method for monitoring graft perfusion and early histological changes after small bowel transplantation.
MATERIALS AND METHODS: Eight dogs (23.3+/-1.1 kg) were submitted to a in situ IHP for 30 min, followed by a 180-min reperfusion period. Cardiac output, mesenteric vein, and intestinal serosal blood flows (SMVBF and SBF, ultrasonic flowprobe); intestinal mucosal-arterial pCO2 gradient (Dt-apCO2, tonometry); and O2-derived variables were evaluated.
RESULTS: IHP induced a reduction in SMVBF (579+/-53 to 321+/-10 mL/min) and SBF, (44.7+/-3.2 to 29.1+/-5.3 mL/min), and an increase in Dt-apCO2 (2+/-2.8 to 20.5+/-4.5 mm Hg). No alterations on systemic metabolic or O2-derived variables were observed. The increase of the Dt-apCO2 correlated with the grade of mucosal injury.
CONCLUSION: IHP induces a proportional reduction on blood flow in all layers of the intestine, and none of the systemic markers of splanchnic ischemia predict the intestinal blood flow disturbances during the early phase of intestinal transplantation. In addition, intestinal pCO2 measurement seems to be a useful way for monitoring graft perfusion and histological changes after hypothermic ischemia and reperfusion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16271367     DOI: 10.1016/j.jss.2005.06.014

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  1 in total

1.  PiCO2 monitoring of transferred jejunum perfusion using an air tonometry technique after hypopharyngeal cancer surgery.

Authors:  Hiroyuki Ozawa; Yorihisa Imanishi; Fumihiro Ito; Yoshihiro Watanabe; Takashi Kato; Hideo Nameki; Kiyoshi Isobe; Kaoru Ogawa
Journal:  Medicine (Baltimore)       Date:  2015-03       Impact factor: 1.889

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.