Literature DB >> 16268833

Effects of an ozone-generating air purifier on indoor secondary particles in three residential dwellings.

H F Hubbard1, B K Coleman, G Sarwar, R L Corsi.   

Abstract

UNLABELLED: The use of indoor ozone generators as air purifiers has steadily increased over the past decade. Many ozone generators are marketed to consumers for their ability to eliminate odors and microbial agents and to improve health. In addition to the harmful effects of ozone, recent studies have shown that heterogeneous and homogeneous reactions between ozone and some unsaturated hydrocarbons can be an important source of indoor secondary pollutants, including free radicals, carbonyls, carboxylic acids, and fine particles. Experiments were conducted in one apartment and two detached single-family dwellings in Austin, TX, to assess the effects of an ozone generator on indoor secondary organic aerosol concentrations in actual residential settings. Ozone was generated using a commercial ozone generator marketed as an air purifier, and particle measurements were recorded before, during, and after the release of terpenes from a pine oil-based cleaning product. Particle number concentration, ozone concentration, and air exchange rate were measured during each experiment. Particle number and mass concentrations increased when both terpenes and ozone were present at elevated levels. Experimental results indicate that ozone generators in the presence of terpene sources facilitate the growth of indoor fine particles in residential indoor atmospheres. Human exposure to secondary organic particles can be reduced by minimizing the intentional release of ozone, particularly in the presence of terpene sources. PRACTICAL IMPLICATIONS: Past studies have shown that ozone-initiated indoor chemistry can lead to elevated concentrations of fine particulate matter, but have generally been completed in controlled laboratory environments and office buildings. We explored the effects of an explicit ozone generator marketed as an air purifier on the formation of secondary organic aerosol mass in actual residential indoor settings. Results indicate significant increases in number and mass concentrations for particles <0.7 microns in diameter, particularly when an ozone generator is used in the presence of a terpene source such as a pine oil-based cleaner. These results add evidence to the potentially harmful effects of ozone generation in residential environments.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16268833     DOI: 10.1111/j.1600-0668.2005.00388.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  7 in total

1.  Indoor formaldehyde removal by three species of Chlorphytum Comosum under the long-term dynamic fumigation system.

Authors:  Jian Li; Jiaochan Zhong; Ting Zhan; Qinghui Liu; Liushui Yan; Mingming Lu
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-19       Impact factor: 4.223

Review 2.  Thirdhand tobacco smoke: emerging evidence and arguments for a multidisciplinary research agenda.

Authors:  Georg E Matt; Penelope J E Quintana; Hugo Destaillats; Lara A Gundel; Mohamad Sleiman; Brett C Singer; Peyton Jacob; Neal Benowitz; Jonathan P Winickoff; Virender Rehan; Prue Talbot; Suzaynn Schick; Jonathan Samet; Yinsheng Wang; Bo Hang; Manuela Martins-Green; James F Pankow; Melbourne F Hovell
Journal:  Environ Health Perspect       Date:  2011-05-31       Impact factor: 9.031

Review 3.  Indoor air quality in public utility environments-a review.

Authors:  Monika Śmiełowska; Mariusz Marć; Bożena Zabiegała
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-24       Impact factor: 4.223

4.  Indoor Air Quality and Sick Building Syndrome: Are Green Buildings Better than Conventional Buildings?

Authors:  Sonal Gawande; Rajnarayan R Tiwari; Prakash Narayanan; Ashwin Bhadri
Journal:  Indian J Occup Environ Med       Date:  2020-03-18

5.  The Air We Breathe: Respiratory Impact of Indoor Air Quality in Chronic Obstructive Pulmonary Disease.

Authors:  Takudzwa Mkorombindo; John R Balmes; Adnan Custovic; Mark T Dransfield
Journal:  Am J Respir Crit Care Med       Date:  2022-02-15       Impact factor: 21.405

6.  Effect of Ozone Gas on Removal of Airborne Particles.

Authors:  Priscilla Alvarenga Agra; Patricia Alvarenga Agra; Marilia Fagury Videira Marceliano-Alves; Greice Maria Silva da Conceição; Sérgio Luiz de Lima Assumpção; Celso de Farias Crespo; Letícia Maria Borsarini Philippi; Renata Ximenes Lins
Journal:  Eur J Dent       Date:  2022-04-18

Review 7.  Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

Authors:  Mariusz Marć; Monika Śmiełowska; Jacek Namieśnik; Bożena Zabiegała
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-30       Impact factor: 4.223

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.