Literature DB >> 16268395

Effect of polymerization modes and resin composite on the temperature rise of human dentin of different thicknesses: an in vitro study.

Flávio Henrique Baggio Aguiar1, Gisele Kanda Peres Barros, Alex José Souza dos Santos, Glaucia Maria Bovi Ambrosano, José Roberto Lovadino.   

Abstract

This in vitro study evaluated the effect of different polymerization modes and the presence of resin composite on the temperature rise (TR) in human dentin of different thicknesses. For this purpose, 90 specimens were assigned to 30 groups (n=3): five polymerization modes (1-conventional; 2-soft-start; 3-high intensity; 4-ramp cure: progressive and high intensity; 5-high intensity with the tip of the light cure at a distance of 1.3 cm for 10 seconds and the tip leaned in the sample); two levels of resin composite presence (absence or presence of resin composite) and three dentin thicknesses (1, 2, 3 mm). During polymerization, temperature was measured by a digital laser thermometer (CMSS2000-SL/SKF). Three-way ANOVA and Tukey tests were performed. There were statistical differences in TR among polymerization modes, presence of resin composite and dentin thicknesses. Within the limits of this study, it can be concluded that 1) conventional and high intensity polymerization modes presented lower TR means, and it was statistically different from soft start, distanced tip and ramp curing polymerization modes; 2) the presence of resin composite showed a statistically significant reduction TR means and 3) the thicker the dentin, the less the temperature rise.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16268395

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  4 in total

1.  Characterization of heat emission of light-curing units.

Authors:  Mohammed A Wahbi; F A Aalam; F I Fatiny; S A Radwan; I Y Eshan; K H Al-Samadani
Journal:  Saudi Dent J       Date:  2012-03-09

2.  Pulpal Temperature Rise: Evaluation after Light Activation of Newer Pulp-Capping Materials and Resin Composite.

Authors:  Jash Lakhani; Vineet Agrawal; Rajesh Mahant; Sonali Kapoor; Dipak Vaghamshi; Arpit Shah
Journal:  Contemp Clin Dent       Date:  2018 Oct-Dec

3.  Thermal rise during photopolymerization and degree of conversion of bulk fill and conventional resin composites.

Authors:  Sayed Mostafa Mousavinasab; Zahra Taromi; Elham Zajkani
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14

4.  Temperature rise within the pulp chamber during composite resin polymerisation using three different light sources.

Authors:  A Santini; C Watterson; V Miletic
Journal:  Open Dent J       Date:  2008-12-05
  4 in total