Literature DB >> 1626671

A pressure regulator for the cuff of a tracheal tube.

D M Miller1.   

Abstract

A regulator is described for the maintenance of a constant pressure difference above airway pressure during positive pressure ventilation in a cuffed tracheal tube. It comprises a tubular threshold valve which is powered by the anaesthetic gas supply source to a breathing system. The valve is interposed between the anaesthetic gas supply machine and the breathing system creating a pressure differential. The upstream pressure is transmitted to the pilot tube supplying the cuff of a tracheal tube via an upstream connection. The valve is suitable only for breathing systems that require a constant gas supply. The regulator was evaluated during anaesthesia, using a modified Mallinkrodt Hi-Lo jet ventilation tube to obtain simultaneous pressure measurements within the cuff and the lumen of the tracheal tube. A greater pressure was demonstrated in the cuff than in the airway and the two traces were approximately parallel throughout the respiratory cycle. The device should prevent excessive cuff inflation pressure and solves the problem of forgetting to let the cuff down before extubation.

Mesh:

Year:  1992        PMID: 1626671     DOI: 10.1111/j.1365-2044.1992.tb02332.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  Effectiveness of Continuous Endotracheal Cuff Pressure Control for the Prevention of Ventilator-Associated Respiratory Infections: An Open-Label Randomized, Controlled Trial.

Authors:  Vu Quoc Dat; Lam Minh Yen; Huynh Thi Loan; Vu Dinh Phu; Nguyen Thien Binh; Ronald B Geskus; Dong Huu Khanh Trinh; Nguyen Thi Hoang Mai; Nguyen Hoan Phu; Nguyen Phu Huong Lan; Tran Phuong Thuy; Nguyen Vu Trung; Nguyen Trung Cap; Dao Tuyet Trinh; Nguyen Thi Hoa; Nguyen Thi Thu Van; Vy Thi Thu Luan; Tran Thi Quynh Nhu; Hoang Bao Long; Nguyen Thi Thanh Ha; Ninh Thi Thanh Van; James Campbell; Ehsan Ahmadnia; Evelyne Kestelyn; Duncan Wyncoll; Guy E Thwaites; Nguyen Van Hao; Le Thanh Chien; Nguyen Van Kinh; Nguyen Van Vinh Chau; H Rogier van Doorn; C Louise Thwaites; Behzad Nadjm
Journal:  Clin Infect Dis       Date:  2022-05-30       Impact factor: 20.999

2.  [Clinical evaluation of a pressure release valve for paediatric cuffed tracheal tubes].

Authors:  S Fertl; V Bernet; A Schmitz; K Woitzek; M Weiss
Journal:  Anaesthesist       Date:  2009-01       Impact factor: 1.041

3.  Maintenance of tracheal tube cuff pressure: where are the limits?

Authors:  Miquel Ferrer; Antoni Torres
Journal:  Crit Care       Date:  2008-01-16       Impact factor: 9.097

  3 in total