This paper describes the procedure for using a Fuji computed radiography (CR) imaging plate (IP) for the measurement of computed tomography (CT) radiation profiles. Two sources of saturation in the data from the IP, signal and quantization, were characterized to establish appropriate exposure and processing conditions for accurate measurements. The IP generated similar profiles compared to those obtained from digitized ready-pack films, except at the profile edges, where the exposure level is low. However, when IP pixel values are converted to exposure, CR and digitized film profiles are in agreement. The full width at half maximum (FWHM) of the CT radiation profile was determined from the relationship between pixel value and exposure and compared to FWHM of the digitized optical density profile from film. To estimate the effect of scattering by the cassette material, radiation profiles were acquired from IPs enclosed in a cassette or in a paper envelope. The presence of the cassette made no difference in the value determined for FWHM. With proper exposure and processing conditions, the FWHM of 5, 10, and 15 mm collimated beams were measured using IPs to be 7.1, 11.9, and 17.0 mm and using film to be 7.2, 12.2, and 16.8 mm, respectively. Our results suggest that, under appropriate conditions, the estimation of the width of the CT radiation profile using Fuji CR is comparable to the measurement from film density described in American Association of Physicists in Medicine (AAPM) Report No. 39. Although our experiment was conducted using Fuji CR, we anticipate that CR plates from other vendors could be successfully used to measure CT beam profiles because of similar empirical relationships between pixel value and exposure.

Entities:  

Mesh:

Year:  2005        PMID: 16266102     DOI: 10.1118/1.1954907

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Method for evaluating bow tie filter angle-dependent attenuation in CT: theory and simulation results.

Authors:  John M Boone
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  Evaluation of different techniques for CT radiation profile width measurement.

Authors:  Steven R Jackson; Salahuddin Ahmad; Yida Hu; Chun Ruan
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

3.  Measurement of table feed speed in modern CT.

Authors:  Atsushi Fukuda; Pei-Jan P Lin; Kosuke Matsubara; Tosiaki Miyati
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

4.  CT radiation profile width measurement using CR imaging plate raw data.

Authors:  Thorarin Albert Bjarnason; Chang-Ying Joseph Yang
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

5.  Estimation of primary radiation output for wide-beam computed tomography scanner.

Authors:  Atsushi Fukuda; Pei-Jan P Lin; Nao Ichikawa; Kosuke Matsubara
Journal:  J Appl Clin Med Phys       Date:  2019-05-02       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.