Fricke gel as a tool for dose distribution verification: optimization and characterization.

S Saur1, T Strickert, E Wasboe, J Frengen.   

Abstract

With the introduction of conformal techniques in radiation therapy, gel dosimetry plays an important role as a 3D dose verification system. There are two main types of gels in use for dosimetry: Fricke gels and polymer gels. The advantages of polymer gels are improved dose response and stability with no diffusion problems. However, the more complicated fabrication procedure and the greater cost compared to Fricke gels makes polymer gels less attractive in routine clinical use. Dose resolution has recently been introduced as a concept for comparing and optimizing the performance of different types of gel dosimeters. This parameter has not yet been investigated for Fricke gels. In this study, the effect on the dose resolution and the diffusion from different gelatine- and Fe2+-concentrations and different pH was evaluated. Increasing the concentration of gelatine from 6 wt% to 10 wt% influenced the diffusion coefficient the most, while reducing the pH from 2.0 to 1.5 had the largest effect on the dose resolution. For a gel consisting of 10 wt% gelatine, 1.0 mM Fe2+ and pH 1.5 the diffusion coefficient was found to be 1.5 mm2 h-1 and the dose resolution was about 4.1% (at 95% confidence level), for a dose of 40 Gy. By evaluating different dose gradients by the gamma-method, the diffusion was shown to have no clinically relevant impact on the dose distribution and plan acceptance within 3 h of irradiation. The results indicate a potential use of Fricke gels for IMRT verification.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16264251     DOI: 10.1088/0031-9155/50/22/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Authors:  Yassir Ben Ahmed; Jérémy Coulaud; Soléakhena Ken; Laure Parent
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

2.  Dose response of three-dimensional silicone-based radiochromic dosimeters for photon irradiation in the presence of a magnetic field.

Authors:  Morten B Jensen; Peter Balling; Simon J Doran; Jørgen B B Petersen; Isak H Wahlstedt; Ludvig P Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-10-19

3.  Effective Atomic Number and Electron Density Determination for Fricke Gel Dosimeters Using Different Methods.

Authors:  Ouiza Moussous
Journal:  J Med Phys       Date:  2022-03-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.