Literature DB >> 16256340

Arm and ankle blood pressure during caesarean section.

S Sanghera1, A North, S Abernethy, I Wrench.   

Abstract

BACKGROUND: We have previously reported that measurement of non-invasive blood pressure during caesarean section under spinal anaesthesia fails in over 50% of cases. We felt that errors would be less likely if blood pressure could be measured at the ankle as it is immobile during caesarean section. The purpose of our study was to determine whether blood pressure measurement at the ankle was equivalent to the arm.
METHOD: Following ethical approval, informed consent was obtained from 30 women scheduled for elective caesarean section. Two non-invasive blood pressure cuffs, one on the upper arm and one on the ankle, were used to measure blood pressures at three timed intervals: before spinal insertion, before surgery and after delivery of the neonate.
RESULTS: Using the method of Bland and Altman we found that there was only marginal agreement between the two methods. On eight out of 15 occasions where there was a greater than 20% fall in arm systolic blood pressure, this was not detected at the ankle.
CONCLUSION: We cannot recommend the use of the ankle to measure blood pressure during caesarean section.

Entities:  

Mesh:

Year:  2005        PMID: 16256340     DOI: 10.1016/j.ijoa.2005.04.016

Source DB:  PubMed          Journal:  Int J Obstet Anesth        ISSN: 0959-289X            Impact factor:   2.603


  2 in total

1.  Continuous Non-Invasive Arterial Pressure Monitoring (ClearSight System) and Ankle Blood Pressure Measurements as Alternatives to Conventional Arm Blood Pressure.

Authors:  Seohee Lee; Jaeyeon Chung; Jinyoung Bae; Youn Joung Cho; Karam Nam; Yunseok Jeon
Journal:  J Clin Med       Date:  2020-11-10       Impact factor: 4.241

2.  Can we use the ankle non-invasive blood pressure during otolaryngologic surgery: an observational study.

Authors:  Sidi Driss El Jaouhari; Mohamed Meziane; Jalal Kessouati; Rachid Razine; Abdelhamid Jaafari; Mustapha Bensghir
Journal:  Pan Afr Med J       Date:  2020-05-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.