Literature DB >> 16254706

The impact of varying volumes in rectal balloons on rectal dose sparing in conformal radiation therapy of prostate cancer. A prospective three-dimensional analysis.

Andrea Hille1, Heinz Schmidberger, Nadja Töws, Elisabeth Weiss, Hilke Vorwerk, Clemens F Hess.   

Abstract

BACKGROUND AND
PURPOSE: The use of a rectal balloon leads to a protection of the posterior rectal wall in irradiation of prostate cancer. The purpose of this analysis was to quantitatively assess the optimal volume in rectal balloons concerning rectal dose sparing in different clinical target volumes (CTVs) in prostate cancer irradiation. PATIENTS AND METHODS: 14 patients with localized prostate cancer undergoing external beam radiotherapy were investigated. The prostate, the entire and the proximal seminal vesicles were delineated as CTV. Treatment plans without a rectal balloon and with a rectal balloon inflated with 40 ml (six patients) or 60 ml air (eight patients) were generated for each CTV and compared concerning rectal dose volume histograms.
RESULTS: The use of a rectal balloon filled with 40 ml air led to no significant advantage in radiation exposure of the rectal wall in all CTVs. The use of a rectal balloon filled with 60 ml air resulted in a significant decrease of the exposed rectal wall volume in all CTVs with a reduced estimated risk for chronic toxicity in case of inclusion of the proximal or entire seminal vesicles into the CTV.
CONCLUSION: The use of a rectal balloon filled with 60 ml air led to a significantly decreased proportion of the irradiated rectal wall for all CTVs. This volume filled in rectal balloons is therefore recommended for use. In case of irradiation of the prostate without the seminal vesicles, the use of a rectal balloon should be considered carefully concerning the patients' imaginable discomfort using a rectal balloon and a questionable advantage concerning the estimated risk for chronic toxicity.

Entities:  

Mesh:

Year:  2005        PMID: 16254706     DOI: 10.1007/s00066-005-1443-2

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  7 in total

1.  Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer.

Authors:  Kenji Takayama; Takashi Mizowaki; Yoshiharu Negoro; Yoshiki Norihisa; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2010-10-05       Impact factor: 3.402

2.  3-D Conformal radiotherapy of localized prostate cancer within an Austrian-German multicenter trial: a prospective study of patients' acceptance of the rectal balloon during treatment.

Authors:  Gregor Goldner; Hans Geinitz; Stefan Wachter; Gerd Becker; Frank Zimmermann; Natascha Wachter-Gerstner; Stefan Glocker; Regina Pötzi; Andre Wambersie; Michael Bamberg; Michael Molls; Horst Feldmann; Richard Pötter
Journal:  Wien Klin Wochenschr       Date:  2006-05       Impact factor: 1.704

3.  Effect of magnesium oxide on interfraction prostate motion and rectal filling in prostate cancer radiotherapy: analysis of a randomized clinical trial.

Authors:  Annemarie M den Harder; Carla H van Gils; Alexis N T J Kotte; Marco van Vulpen; Irene M Lips
Journal:  Strahlenther Onkol       Date:  2014-04-24       Impact factor: 3.621

Review 4.  Reducing rectal injury during external beam radiotherapy for prostate cancer.

Authors:  Riccardo Valdagni; Tiziana Rancati
Journal:  Nat Rev Urol       Date:  2013-05-14       Impact factor: 14.432

Review 5.  Reducing rectal injury in men receiving prostate cancer radiation therapy: current perspectives.

Authors:  Nicholas A Serrano; Noah S Kalman; Mitchell S Anscher
Journal:  Cancer Manag Res       Date:  2017-07-28       Impact factor: 3.989

6.  Positional reproducibility and effects of a rectal balloon in prostate cancer radiotherapy.

Authors:  Jae Ho Cho; Chang-Geol Lee; Dae Ryong Kang; Jooho Kim; Sangkyu Lee; Chang-Ok Suh; Jinsil Seong; Yang Gun Suh; Ikjae Lee; Gwi Eon Kim
Journal:  J Korean Med Sci       Date:  2009-09-24       Impact factor: 2.153

7.  Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.

Authors:  Felix Böckelmann; Florian Putz; Karoline Kallis; Sebastian Lettmaier; Rainer Fietkau; Christoph Bert
Journal:  Strahlenther Onkol       Date:  2020-03-10       Impact factor: 3.621

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.