Literature DB >> 16253974

A prospective study of the forearm bone density of users of etonorgestrel- and levonorgestrel-releasing contraceptive implants.

Luis Bahamondes1, Cecilia Monteiro-Dantas, Ximena Espejo-Arce, Arlete M Dos Santos Fernandes, Jeffrey F Lui-Filho, Marcos Perrotti, Carlos A Petta.   

Abstract

BACKGROUND: The aim of the study was to compare bone mineral density (BMD) before insertion and at 18 months of use of etonorgestrel- and levonorgestrel-releasing contraceptive implants.
METHODS: One hundred and eleven women, 19-43 years of age, were randomly allocated to two groups: 56 to etonorgestrel and 55 to levonorgestrel. BMD was evaluated at the midshaft of the ulna and at the distal radius of the non-dominant forearm using dual-energy X-ray absorptiometry before insertion and at 18 months of use.
RESULTS: There was no difference in baseline demographic or anthropometric characteristics, or in BMD of users of either model of implant. BMD was significantly lower at 18 months of use at the midshaft of the ulna in both groups of users. However, no difference was found at the distal radius. Multiple linear regression analysis showed that the variables associated with BMD at 18 months of use in both implant groups were baseline BMD, body mass index (BMI) and difference in BMI (0 versus 18 months of use).
CONCLUSIONS: Women of 19-43 years of age using either one of the implants showed lower BMD at 18 months of use at the midshaft of the ulna, however, without a difference at the distal radius.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16253974     DOI: 10.1093/humrep/dei358

Source DB:  PubMed          Journal:  Hum Reprod        ISSN: 0268-1161            Impact factor:   6.918


  3 in total

Review 1.  Update on hormonal contraception and bone density.

Authors:  Michelle M Isley; Andrew M Kaunitz
Journal:  Rev Endocr Metab Disord       Date:  2011-06       Impact factor: 6.514

2.  An Observational Study on the Application of the Second-generation Radiopaque Subcutaneous Implant.

Authors:  Xiaoou Xu; Xiaojuan Zhang; Xueniu Yang
Journal:  Iran J Pharm Res       Date:  2021       Impact factor: 1.696

3.  A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants.

Authors:  Cecilia Monteiro-Dantas; Ximena Espejo-Arce; Jeffrey F Lui-Filho; Arlete M Fernandes; Ilza Monteiro; Luis Bahamondes
Journal:  Reprod Health       Date:  2007-11-12       Impact factor: 3.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.