Literature DB >> 16249849

An assessment of the effects of two types of bioresorbable barriers to prevent postoperative intra-abdominal adhesions in rats.

Huseyin Ayhan Kayaoglu1, Namik Ozkan, Selcuk Mevlut Hazinedaroglu, Omer Faik Ersoy, Resit Dogan Koseoglu.   

Abstract

PURPOSE: This study assessed and compared the efficacy of two types of bioresorbable membranes in the prevention of postoperative adhesion under clean contaminated and bacterial peritonitis conditions using a cecal ligation and puncture model in rats.
METHODS: Wistar albino rats (n = 72) were divided into six groups. Bacterial peritonitis was induced using a cecal ligation and puncture model in groups 2, 4, and 6. Groups 1, 3, and 5 served as controls for clean contaminated procedures in the absence of bacterial peritonitis. Groups 1 and 2 were the untreated clean contaminated and bacterial peritonitis groups and served as controls for the effect of the bioresorbable membranes in each condition. In groups 3 and 4, a 1.5 x 3 cm USP glycerol/sodium hyaluronate/carboxymethylcellulose membrane was wrapped around the cecal resection area and a 2 x 4 cm membrane was left under the incision. The oxidized regenerated cellulose membrane was similarly applied in groups 5 and 6. Four weeks later, the adhesions were evaluated. In addition, fibrosis and inflammation were observed histopathologically.
RESULTS: Adhesion development (P = .008), fibrosis (P = .008), and inflammation (P = .0001) differed among the groups. Both materials increased adhesion formation in the bacterial peritonitis condition. Increased fibrotic activity was detected in all material-applied groups under both conditions. In addition, more inflammation was detected in the groups that received the application of a material, especially in the presence of bacterial peritonitis.
CONCLUSION: Neither material prevented adhesions in clean contaminated conditions. Moreover, they increased adhesion formation in bacterial peritonitis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16249849     DOI: 10.1007/s00595-004-3050-8

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  36 in total

1.  Fibrinolytic activity in the abdominal cavity of rats with faecal peritonitis.

Authors:  H van Goor; J S de Graaf; J Grond; W J Sluiter; J van der Meer; V J Bom; R P Bleichrodt
Journal:  Br J Surg       Date:  1994-07       Impact factor: 6.939

Review 2.  Sepsis and septic shock--a review of laboratory models and a proposal.

Authors:  K A Wichterman; A E Baue; I H Chaudry
Journal:  J Surg Res       Date:  1980-08       Impact factor: 2.192

Review 3.  Barrier agents for preventing adhesions after surgery for subfertility.

Authors:  C Farquhar; P Vandekerckhove; A Watson; A Vail; D Wiseman
Journal:  Cochrane Database Syst Rev       Date:  2000

4.  Polyurethane-covered dacron mesh versus polytetrafluoroethylene DualMesh for intraperitoneal hernia repair in rats.

Authors:  Jürgen Zieren; Marco Paul; Thomas Osei-Agyemang; Folkert Maecker; Jochen M Müller
Journal:  Surg Today       Date:  2002       Impact factor: 2.549

5.  Hyaluronic acid-carboxymethylcellulose film and perianastomotic adhesions in previously irradiated rats.

Authors:  D Bowers; R B Raybon; C R Wheeless
Journal:  Am J Obstet Gynecol       Date:  1999-12       Impact factor: 8.661

Review 6.  Preclinical evaluation of Seprafilm bioresorbable membrane.

Authors:  J W Burns; M J Colt; L S Burgees; K C Skinner
Journal:  Eur J Surg Suppl       Date:  1997

Review 7.  Colostomy closure. Ochsner Clinic experience.

Authors:  D A Khoury; D E Beck; F G Opelka; T C Hicks; A E Timmcke; J B Gathright
Journal:  Dis Colon Rectum       Date:  1996-06       Impact factor: 4.585

8.  The efficacy of Interceed(TC7)* for prevention of reformation of postoperative adhesions on ovaries, fallopian tubes, and fimbriae in microsurgical operations for fertility: a multicenter study. Nordic Adhesion Prevention Study Group.

Authors: 
Journal:  Fertil Steril       Date:  1995-04       Impact factor: 7.329

9.  Collagen-PVP, a collagen synthesis modulator, decreases intraperitoneal adhesions.

Authors:  Carlos R Cervantes-Sánchez; Enrique Olaya; Manuel Testas; Norberto Garcia-López; Gabriel Coste; Gerardo Arrellin; Adrián Luna; Fernando Edgar Krötzsch
Journal:  J Surg Res       Date:  2003-03       Impact factor: 2.192

Review 10.  Reversal of Hartmann's procedure: effect of timing and technique on ease and safety.

Authors:  J O Keck; B T Collopy; P J Ryan; R Fink; J R Mackay; R J Woods
Journal:  Dis Colon Rectum       Date:  1994-03       Impact factor: 4.585

View more
  4 in total

1.  In-vivo and in-vitro histological evaluation of two commercially available acellular dermal matrices.

Authors:  J A Faleris; R M C Hernandez; D Wetzel; R Dodds; D C Greenspan
Journal:  Hernia       Date:  2010-11-20       Impact factor: 4.739

2.  Comparison of the two types of bioresorbable barriers to prevent intra-abdominal adhesions in rats.

Authors:  Eren Ersoy; Vedat Ozturk; Aylin Yazgan; Mehmet Ozdogan; Haldun Gundogdu
Journal:  J Gastrointest Surg       Date:  2008-09-07       Impact factor: 3.452

3.  Chitosan conduit combined with hyaluronic acid prevent sciatic nerve scar in a rat model of peripheral nerve crush injury.

Authors:  Runxin Li; Huawei Liu; Haitao Huang; Wenting Bi; Rongzeng Yan; Xinying Tan; Weisheng Wen; Chao Wang; Wenling Song; Yanhua Zhang; Feng Zhang; Min Hu
Journal:  Mol Med Rep       Date:  2018-01-08       Impact factor: 2.952

4.  Anti-Adhesion Effect of Composite Film Materials Based on Glycoluril-Modified Sodium Carboxymethyl Cellulose.

Authors:  A A Bakibaev; V P Tuguldurova; M V Lyapunova; V V Ivanov; O A Kaidash; E V Udut; M V Bukterov; E E Buyko; A S Kasyanova; V S Malkov
Journal:  Sovrem Tekhnologii Med       Date:  2021-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.