Literature DB >> 16245285

Effects of adhesive systems and luting agents on bonding of fiber posts to root canal dentin.

Francesca Monticelli1, Raquel Osorio, Alberto Albaladejo, Fatima S Aguilera, Marco Ferrari, Franklin R Tay, Manuel Toledano.   

Abstract

The study evaluated the influence of different luting materials on the microtensile bond strength of glass fiber posts to root canal dentin. Thirty extracted maxillary premolars were endodontically treated, and the roots were prepared for post cementation using the FRC Postec system (Vivadent). Two luting materials (Multilink, Vivadent and Clearfil Photo Core, Kuraray) were used in combination with three adhesive: Multilink Primer (Vivadent), Clearfil Photo Bond, and Clearfil New Bond (Kuraray). A composite build-up was performed around the root to provide adequate gripping during testing. Specimens were cut to obtain beams with the post in the center and with the radicular dentin overlaid by the composite build-up on each side. Microtensile testing was performed with a universal testing machine at a cross-head speed of 0.5 mm/min. The failure mode was classified under a stereomicroscope and four representative beams of each group were selected for SEM analysis. Bond strength data that were analyzed with two-way ANOVA and Student-Newman-Keuls multiple comparisons tests revealed that adhesive systems, luting materials, and the interaction between these two factors significantly influenced the bond strength results (p < 0.01). Multilink applied with its own adhesive system obtained the best results, while the lowest bond strength was achieved with clearfil photo core in combination with multilink primer.

Mesh:

Substances:

Year:  2006        PMID: 16245285     DOI: 10.1002/jbm.b.30420

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Effects of post surface treatments including Er:YAG laser with different parameters on the pull-out bond strength of the fiber posts.

Authors:  Hakan Arslan; Duygu Kurklu; Leyla Benan Ayrancı; Cagatay Barutcigil; Cenk Burak Yılmaz; Ertugrul Karatas; Hüseyin Sinan Topçuoğlu
Journal:  Lasers Med Sci       Date:  2013-11-27       Impact factor: 3.161

2.  Push-out bond strength of different translucent fiber posts cemented with self-adhesive resin cement.

Authors:  João Fernando Bazzo; Maria Beatriz Bergonse Pereira Pedriali; Ricardo Danil Guiraldo; Sandrine Bittencourt Berger; Sandra Kiss Moura; Rodrigo Varella de de Carvalho
Journal:  J Conserv Dent       Date:  2016 Nov-Dec

3.  Comparison between two post-dentin bond strength measurement methods.

Authors:  Laikuan Zhu; Yuping Li; Yung-Chung Chen; Carola A Carrera; Chong Wu; Alex Fok
Journal:  Sci Rep       Date:  2018-02-05       Impact factor: 4.379

4.  Resistance to fracture of endodontically treated teeth: Influence of the post systems and cements.

Authors:  Luanne Mara Rodrigues De Matos; Lucas Portela Oliveira; Aryvelto Miranda Silva; Jessica Katarine De Abreu Silva; Marcelo Lopes Silva
Journal:  Dent Res J (Isfahan)       Date:  2020-12-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.