Literature DB >> 16243282

Determination of concentration and binding affinity of antibody fragments by use of surface plasmon resonance.

Yasufumi Kikuchi1, Shinsuke Uno, Masahiko Nanami, Yasushi Yoshimura, Shin-ichiro Iida, Naoshi Fukushima, Masayuki Tsuchiya.   

Abstract

An assay method using a surface plasmon resonance (SPR) biosensor has been developed that allows quantitative measurement of the specific antibody concentration in crude materials. By injecting non-labeled antibody samples onto a biosensor surface on which antigen was immobilized at high densities, the concentration of active antibodies can be accurately measured. To clarify applicability of this method to pharmacokinetic studies, the concentration of active antibodies in mouse plasma was measured for 4 h after injection of antibodies in mice. Although this period of measurement might be insufficient for determining the pharmacokinetics of blood pool clearance, this method has some advantages over conventional methods in measurement of single-chain antibody fragment (scFv) concentrations. Using the SPR biosensor, scFv and antibodies without epitope tag peptides were easily detected in real time, requiring as little as 20 mul of blood sample. Moreover, from the apparent dissociation rate in the dissociation phase of the sensorgrams, we could identify whether the antibody fragments existed as bivalent or monovalent in animal blood. We also evaluated the antigen binding activity of the scFvs against human CD47 and found scFvs had slightly weak affinity to their antigen (K(D), about 10 nM) compared with F(ab')2 and Fab' fragments (K(D), about 3-4 nM). This assay method promises to be a convenient tool for quality control, screening, and simple pharmacokinetic analysis of antibody fragments and other recombinant proteins not having epitope tags.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16243282     DOI: 10.1263/jbb.100.311

Source DB:  PubMed          Journal:  J Biosci Bioeng        ISSN: 1347-4421            Impact factor:   2.894


  2 in total

1.  Bayesian Estimation of the Active Concentration and Affinity Constants Using Surface Plasmon Resonance Technology.

Authors:  Feng Feng; Thomas B Kepler
Journal:  PLoS One       Date:  2015-06-22       Impact factor: 3.240

2.  A Rapid Method for Direct Quantification of Antibody Binding-Site Concentration in Serum.

Authors:  Erwin G Abucayon; Connor Whalen; Oscar B Torres; Alexander J Duval; Agnieszka Sulima; Joshua F G Antoline; Therese Oertel; Rodell C Barrientos; Arthur E Jacobson; Kenner C Rice; Gary R Matyas
Journal:  ACS Omega       Date:  2022-07-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.