Literature DB >> 16242474

LIFEBRIDGE: a portable, modular, rapidly available "plug-and-play" mechanical circulatory support system.

Uwe Mehlhorn1, Michael Brieske, Uwe M Fischer, Markus Ferrari, Patrick Brass, Juergen H Fischer, Hans-R Zerkowski.   

Abstract

PURPOSE: We describe the LIFEBRIDGE, a portable, modular, rapidly available "plug-and-play" mechanical circulatory support system, and report its experimental safety evaluation. DESCRIPTION: The modular construction consists of a disposable patient module with cardiopulmonary bypass circuit, control module, and base module with power supply, embedded PC, and user interface. The system weighs about 20 kg, has a modular design, and has semi-automatic priming that allows action within 5 minutes, and a 7-step air elimination program that prevents air embolization. EVALUATION: In eight pigs (85 +/- 10 kg) we investigated this system using central (right atrium and ascending aorta) cannulation (n = 4) or peripheral (iliac) cannulation (n = 4). Pump flows were 5.7 +/- 0.2 L/min with central and 4.1 +/- 0.2 L/min with peripheral cannulation, yielding sufficient animal perfusion and gas exchange. Using an intraaortic 8-MHz Doppler device, we demonstrated that venous air boluses of up to 100 mL were effectively removed, thus avoiding air embolization. Changing heights between animals and LIFEBRIDGE did not affect its proper action.
CONCLUSIONS: This initial evaluation demonstrates that the LIFEBRIDGE is rapidly available, provides adequate perfusion and gas exchange, and operates safely even under simulated transport conditions.

Entities:  

Mesh:

Year:  2005        PMID: 16242474     DOI: 10.1016/j.athoracsur.2005.03.040

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Ground transportation of a pediatric patient on ECMO support.

Authors:  David Machin; Richard Scott; Aimee Hurst
Journal:  J Extra Corpor Technol       Date:  2007-06

Review 2.  [Therapy of cardiogenic shock after myocardial infarction].

Authors:  M Ferrari; H R Figulla
Journal:  Internist (Berl)       Date:  2008-09       Impact factor: 0.743

3.  Principle and basic property of the sequential flow pump.

Authors:  Shintaro Hara; Erina Maeno; Xinyang Li; Terumi Yurimoto; Takashi Isoyama; Itsuro Saito; Toshiya Ono; Yusuke Abe
Journal:  J Artif Organs       Date:  2017-04-19       Impact factor: 1.731

Review 4.  [Cardiogenic shock].

Authors:  S Rasche; C Georgi
Journal:  Anaesthesist       Date:  2012-03       Impact factor: 1.041

5.  RE.: Extracorporeal circulatory systems in the interhospital transfer of critically ill patients: experience of a single institution.

Authors:  Peter Feindt; Hannan Dalyanoglu; Artur Lichtenberg
Journal:  Ann Saudi Med       Date:  2010 Mar-Apr       Impact factor: 1.526

6.  [Cardiogenic shock].

Authors:  S Rasche; C Georgi
Journal:  Herz       Date:  2013-03       Impact factor: 1.443

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.