Literature DB >> 16240190

Air pollution and heat exposure study in the workplace in a glass manufacturing unit in India.

A D Bhanarkar1, A Srivastava, A E Joseph, Rakesh Kumar.   

Abstract

Air pollution in the workplace environment due to industrial operation have been found to cause serious occupational health hazard. Similarly, heat stress is still most neglected occupational hazard in the tropical and subtropical countries like India. The hot climate augments the heat exposure close to sources like furnaces. In this study an attempt is made to assess air pollution and heat exposure levels to workers in the workplace environment in glass manufacturing unit located in the State of Gujarat, India. Samples for workplace air quality were collected for SPM, SO(2), NO(2) and CO(2) at eight locations. Results of workplace air quality showed 8-hourly average concentrations of SPM: 165-9118 microg/m(3), SO(2): 6-9 microg/m(3) and NO(2): 5-42 microg/m(3), which were below the threshold limit values of workplace environment. The level of CO(2) in workplace air of the plant was found to be in the range 827-2886 microg/m(3), which was below TLV but much higher than the normal concentration for CO(2) in the air (585 mg/m(3)). Indoor heat exposure was studied near the furnace and at various locations in an industrial complex for glass manufacturing. The heat exposure parameters including the air temperature, the wet bulb temperature, and the globe parameters were measured. The Wet Bulb Globe Temperature (WBGT), an indicator of heat, exceeded ACGIH TLVs limits most of the time at all the locations in workplace areas. The recommended duration of work and rest have also been estimated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16240190     DOI: 10.1007/s10661-005-5839-3

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  2 in total

1.  Assessment of air pollution from small scale industry.

Authors:  A D Bhanarkar; D G Gajghate; M Z Hasan
Journal:  Environ Monit Assess       Date:  2002-12       Impact factor: 2.513

Review 2.  Ambient particles and health: lines that divide.

Authors:  S Vedal
Journal:  J Air Waste Manag Assoc       Date:  1997-05       Impact factor: 2.235

  2 in total
  2 in total

1.  Assessment of thermal environments: working conditions in the portuguese glass industry.

Authors:  A Virgílio M Oliveira; Adélio R Gaspar; António M Raimundo; Divo A Quintela
Journal:  Ind Health       Date:  2017-08-19       Impact factor: 2.179

Review 2.  Health impacts of workplace heat exposure: an epidemiological review.

Authors:  Jianjun Xiang; Peng Bi; Dino Pisaniello; Alana Hansen
Journal:  Ind Health       Date:  2013-12-21       Impact factor: 2.179

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.