Severe hypoxia due to ventilation-perfusion mismatch caused by aortic arch aneurysm.

T Sugimoto1, K Ogawa, T Asada, N Mukohara, M Nishiwaki.   

Abstract

We report a very rare case of hugh aortic arch aneurysm associated with aortic restenosis, which caused severe hypoxia due to ventilation-perfusion mismatch by compression of the left main bronchus and the right pulmonary artery. Aortic arch replacement was performed under circulatory arrest and deep hypothermia in addition to aortic valve replacement as a redo operation, and consequently such hypoxia was relieved.

Entities:  

Mesh:

Year:  1992        PMID: 1623786     DOI: 10.1378/chest.102.1.322

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  1 in total

1.  Hemodynamic collapse induced by general anesthesia in a patient with an unruptured thoracic aortic aneurysm: a case report.

Authors:  Oto Inoue; Hisayoshi Murai; Shuichi Kaneko; Soichiro Usui; Hiroshi Furusho; Masayuki Takamura
Journal:  BMC Cardiovasc Disord       Date:  2013-12-27       Impact factor: 2.298

  1 in total