Literature DB >> 16237244

Comparison between effective doses for voxel-based and stylized exposure models from photon and electron irradiation.

R Kramer1, H J Khoury, J W Vieira.   

Abstract

For the last two decades, the organ and tissue equivalent dose as well as effective dose conversion coefficients recommended by the International Commission on Radiological Protection (ICRP) have been determined with exposure models based on stylized MIRD5-type phantoms representing the human body with its radiosensitive organs and tissues according to the ICRP Reference Man released in Publication No. 23, on Monte Carlo codes sometimes simulating rather simplified radiation physics and on tissue compositions from different sources. Meanwhile the International Commission on Radiation Units and Measurements (ICRU) has published reference data for human tissue compositions in Publication No. 44, and the ICRP has released a new report on anatomical reference data in Publication No. 89. As a consequence many of the components of the traditional stylized exposure models used to determine the effective dose in the past have to be replaced: Monte Carlo codes, human phantoms and tissue compositions. This paper presents results of comprehensive investigations on the dosimetric consequences to be expected from the replacement of the traditional stylized exposure models by the voxel-based exposure models. Calculations have been performed with the EGS4 Monte Carlo code for external and internal exposures to photons and electrons with the stylized, gender-specific MIRD5-type phantoms ADAM and EVA on the one hand and with the recently developed tomographic or voxel-based phantoms MAX and FAX on the other hand for a variety of exposure conditions. Ratios of effective doses for the voxel-based and the stylized exposure models will be presented for external and internal exposures to photons and electrons as a function of the energy and the geometry of the radiation field. The data indicate that for the exposure conditions considered in these investigations the effective dose may change between +60% and -50% after the replacement of the traditional exposure models by the voxel-based exposure models.

Entities:  

Mesh:

Year:  2005        PMID: 16237244     DOI: 10.1088/0031-9155/50/21/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Assessment of radiation dose in nuclear cardiovascular imaging using realistic computational models.

Authors:  Tianwu Xie; Choonsik Lee; Wesley E Bolch; Habib Zaidi
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

2.  Organ doses, effective doses, and risk indices in adult CT: comparison of four types of reference phantoms across different examination protocols.

Authors:  Yakun Zhang; Xiang Li; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.506

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.