Literature DB >> 16235816

Design and construction of Thermoelectric Footwear Heating System for illness feet.

Hakan Işik1.   

Abstract

In this study, a Thermoelectric Footwear Heating System is developed to use in cold weather conditions. The temperature is controlled by an analog electronic control system. Thermoelectric module is used to heat the bottom of the foot. A negative temperature coefficient (NTC) temperature sensor is used to sense the temperature and the temperature is controlled by an electronic circuit proportionally. A 3.5 V, 5000 mAh rechargeable battery is used as the power source. The temperature range of the system is between +15 degrees C and +50 degrees C. Developed footwear heating system is tested against various temperature conditions, and offer better results in the case of heating the illness feet.

Mesh:

Year:  2005        PMID: 16235816     DOI: 10.1007/s10916-005-6131-3

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  9 in total

1.  Control of dental prosthesis system with microcontroller.

Authors:  M Kapidere; S Müldür; I Güler
Journal:  J Med Syst       Date:  2000-04       Impact factor: 4.460

2.  Tactile discrimination and skin temperature.

Authors:  K A PROVINS; R MORTON
Journal:  J Appl Physiol       Date:  1960-01       Impact factor: 3.531

3.  Manual dexterity in the cold.

Authors:  W H TEICHNER
Journal:  J Appl Physiol       Date:  1957-11       Impact factor: 3.531

4.  Finger numbness and skin temperature.

Authors:  A W MILLS
Journal:  J Appl Physiol       Date:  1956-11       Impact factor: 3.531

5.  Finger numbness in very cold winds.

Authors:  N H MACKWORTH
Journal:  J Appl Physiol       Date:  1953-03       Impact factor: 3.531

6.  The influence of cold upon the efficiency of man.

Authors:  S M HORVATH; A FREEDMAN
Journal:  J Aviat Med       Date:  1947-04

7.  Dexterity performance and reduced ambient temperature.

Authors:  M W Riley; D J Cochran
Journal:  Hum Factors       Date:  1984-04       Impact factor: 2.888

8.  Restoration of thermoregulatory response to body cooling by cooling hands and feet.

Authors:  R N Van Someren; S R Coleshaw; P J Mincer; W R Keatinge
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-11

9.  Blood storage and transport in the field using a portable thermoelectric refrigerator: assessment of potential use.

Authors:  D H Haynes; W P Monaghan
Journal:  Mil Med       Date:  1984-04       Impact factor: 1.437

  9 in total
  2 in total

1.  The design of thermoelectric footwear heating system via fuzzy logic.

Authors:  Hakan Işik; Esra Saraçoğlu
Journal:  J Med Syst       Date:  2007-12       Impact factor: 4.460

2.  Use of a novel smart heating sleeping bag to improve wearers' local thermal comfort in the feet.

Authors:  W F Song; C J Zhang; D D Lai; F M Wang; K Kuklane
Journal:  Sci Rep       Date:  2016-01-13       Impact factor: 4.379