Literature DB >> 16233839

Simultaneous removal of H2S and NH3 in biofilter inoculated with Acidithiobacillus thiooxidans TAS.

Eun Young Lee1, Kyung-Suk Cho, Hee Wook Ryu.   

Abstract

H2S and NH3 gases are toxic, corrosive and malodorous air pollutants. Although there are numerous well-established physicochemical techniques presently available for the treatment of these gases, the growing demand for a more economical and improved process has prompted investigations into biological alternatives. In biological treatment methods, H2S is oxidized to SO4(2-) by sulfur-oxidizing bacteria, and then NH3 is removed by chemical neutralization with SO4(2-) to (NH4)2SO4. Since the accumulated (NH4)2SO4 can inhibit microbial activity, it is important to utilize an effective sulfur-oxidizing bacterium that has tolerance to high concentrations of (NH4)2SO4 for the simultaneous removal of H2S and NH3. In this study, a sulfur-oxidizing bacterium with tolerance to high concentrations of (NH4)2SO4 was isolated from activated sludge and identified as Acidithiobacillus thiooxidans TAS. A. thiooxidans TAS could display its sulfur-oxidizing activity in a medium supplemented with 60 g.l(-1) (NH4)2SO4, even though its growth and sulfur-oxidizing activity were completely inhibited in 80 g.l(-1) (NH4)2SO4. When H2S alone was supplied to a ceramic biofilter inoculated with A. thiooxidans TAS, an almost 100% H2S removal efficiency was maintained until the inlet H2S concentration was increased up to 900 microl.l(-1) and the space velocity up to 500 h(-1), at which the amount of H2S eliminated was 810 g-S.m(-3).h(-1). However, when NH3 (50-500 microl.l(-1)) was simultaneously supplied to the biofilter with H2S, the maximum amount of H2S eliminated decreased to 650 g-S.m(-3).h(-1). The inhibition of H2S removal by low NH3 concentrations (50-200 microl.l(-1)) was similar to that by high NH3 concentrations (300-500 microl.l(-1)). The critical inlet H2S load that resulted in over 99% removal was determined as 400 g-S.m(-3).h(-1) in the presence of NH3.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16233839     DOI: 10.1263/jbb.99.611

Source DB:  PubMed          Journal:  J Biosci Bioeng        ISSN: 1347-4421            Impact factor:   2.894


  2 in total

1.  Hydrogen sulfide removal from air by Acidithiobacillus thiooxidans in a trickle bed reactor.

Authors:  M Ramirez; J M Gómez; D Cantero; J Páca; M Halecký; E I Kozliak; M Sobotka
Journal:  Folia Microbiol (Praha)       Date:  2009-11-24       Impact factor: 2.099

2.  A comparative evaluation of dried activated sludge and mixed dried activated sludge with rice husk silica to remove hydrogen sulfide.

Authors:  Seyed Mahmoud Mehdinia; Puziah Abdul Latif; Hassan Taghipour
Journal:  Iranian J Environ Health Sci Eng       Date:  2013-03-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.