Literature DB >> 16230982

Measured maximal oxygen uptake in a multi-stage shuttle test and treadmill-run test in trained athletes.

A R Aziz1, M Y H Chia, K C Teh.   

Abstract

AIM: The aims of the study were: i) to compare the measured maximal oxygen uptake (MVO2max) during the 20 m multi-stage shuttle test (MST) with MVO2max during an incremental treadmill-run test (TRT), and ii) to establish the reliability of MVO2max during MST, in trained athletes. EXPERIMENTAL
DESIGN: 8 well-trained endurance-athletes (END) and 8 athletes involved in team games (GAM) performed the MST twice (i.e. MST1 and MST2) and the TRT once, in 3 separate sessions. MEASURES: MVO2maxx attained in the MST and TRT was measured using a portable respiratory analyser (model K4 RQ, Cosmed).
RESULTS: MVO2max attained in the MST and TRT were significantly different for the END athletes (4.1+/-0.28 vs 4.45+/-0.31 Lxmin-1, P<0.05) but not for GAM athletes (4.01+/-0.51 vs 4.1+/-0.59 Lxmin-1, P>0.05). The 95% limits of agreement for MVO2max in the MST in Lxmin-1 were -0.67 to 0.27. MVO2max in MST1 and MST2 were not significantly different for END athletes (4.18+/-0.39 vs 4.1+/-0.28 Lxmin-1, P>0.05) and GAM athletes (4.01+/-0.55 vs 4.01+/-0.51 Lxmin-1, P>0.05). Reliability indicators for MVO2max in Lxmin-1 for MST test-retest were: typical error (TE)=0.14, coefficient of variation (CV)=3.5 and intra-class correlation (ICC)=0.90.
CONCLUSION: MVO2max in the MST was lower than that measured in the TRT for the END athletes but not for the GAM athletes. Sport-specificity was an important consideration, especially when testing END athletes for VO2max. MVO2max in the MST showed acceptable levels of reproducibility.

Entities:  

Mesh:

Year:  2005        PMID: 16230982

Source DB:  PubMed          Journal:  J Sports Med Phys Fitness        ISSN: 0022-4707            Impact factor:   1.637


  2 in total

Review 1.  Criterion-Related Validity of the 20-M Shuttle Run Test for Estimating Cardiorespiratory Fitness: A Meta-Analysis.

Authors:  Daniel Mayorga-Vega; Pablo Aguilar-Soto; Jesús Viciana
Journal:  J Sports Sci Med       Date:  2015-08-11       Impact factor: 2.988

2.  A re-appraisal of the reliability of the 20 m multi-stage shuttle run test.

Authors:  Kevin L Lamb; Louise Rogers
Journal:  Eur J Appl Physiol       Date:  2007-03-07       Impact factor: 3.346

  2 in total