Literature DB >> 16227479

Noise in subtraction images made from pairs of bitewing radiographs: a comparison between two subtraction programs.

F Haiter-Neto1, A Wenzel.   

Abstract

OBJECTIVES: To compare noise in subtraction images produced by two subtraction programs.
METHODS: Twenty-five pairs of bitewing radiographs exposed under clinical conditions were subtracted using two digital subtraction programs: X-PoseIt (XP) software and EMAGO/Advanced 3.43 (EM) software. Four reference points were located between the mesial surface of the upper first premolar and the distal surface of the upper first molar (the region of interest) on the same anatomical structures using XP and EM. The standard deviation (SD) of the histogram defining the distribution of the shades of grey in the region of interest was used as the statistical parameter for comparing noise in the subtraction images created by the two subtraction programs.
RESULTS: The mean and median grey shade value was lower with EM software (126.9, 126) than with XP software (128.3, 128) (P < 0.05). For the SD, the mean value was significantly lower with XP (6.2) than with EM (7.8) (P < 0.05). The range of the SD values was larger for EM (3.6-12.8) than XP (3.3-9.9).
CONCLUSIONS: The standard deviation of the grey shade histogram showed that subtraction images produced with X-PoseIt software were statistically less noisy than images produced with EMAGO/Advanced 3.43 software.

Mesh:

Year:  2005        PMID: 16227479     DOI: 10.1259/dmfr/15631269

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  A retrospective study of digital subtraction technique to detect sclerotic changes in alveolar bone on intraoral radiographs of bisphosphonate-treated patients.

Authors:  M U Zaman; T Nakamoto; K Tanimoto
Journal:  Dentomaxillofac Radiol       Date:  2013-10-29       Impact factor: 2.419

2.  Assessment of three methods of geometric image reconstruction for digital subtraction radiography.

Authors:  Polyane M Queiroz; Matheus L Oliveira; Jefferson L O Tanaka; Milton G Soares; Francisco Haiter-Neto; Evelise Ono
Journal:  Dentomaxillofac Radiol       Date:  2016-07-19       Impact factor: 2.419

3.  Reproducibility and diagnostic value of a new wedge-guided bitewing image receptor-holding device.

Authors:  Deivi Cascante-Sequeira; Hugo Gaêta-Araujo; Danieli Moura Brasil; Deborah Queiroz Freitas; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2021-08-31       Impact factor: 2.419

4.  Reduction of scratch or dirt artifacts on intraoral radiographs using dual imaging plates in image processing.

Authors:  Yusuke Imanishi; Takahito Sekiguchi; Masao Kato; Hideaki Kimoto; Toshihiko Amemiya; Ko Dezawa; Kunihito Matsumoto; Yoshinori Arai
Journal:  Oral Radiol       Date:  2022-08-31       Impact factor: 1.882

5.  Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Liogi Iwaki Filho; Alfredo De Franco Queiroz; Lucas Bachegas Gomes Geron
Journal:  Contemp Clin Dent       Date:  2013-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.