Literature DB >> 16226158

Determination of several psychiatric drugs in whole blood using capillary gas-liquid chromatography with nitrogen phosphorus detection: comparison of two solid phase extraction procedures.

Carolina Sánchez de la Torre1, María A Martínez, Elena Almarza.   

Abstract

A simple and reliable gas chromatographic method with nitrogen-phosphorus detection without derivatization was developed for the detection of several psychiatric drugs in whole blood as part of systematic toxicological analyses (STA). Drugs included mirtazapine, chlorpromazine, methotrimeprazine (levomepromazine), clothiapine, olanzapine, clozapine, haloperidol, and thioridazine. All drugs were studied at concentrations of 100-2,000 microg/L, except haloperidol that was studied at concentrations of 400-8,000 microg/L. In order to select the best blood purification procedure and therefore increase the signal to noise ratio we have compared two solid-phase extraction (SPE) columns, Chem Elut and Bond Elut Certify, for their recovery, precision, sensitivity and matrix purification efficiency. Recoveries for these drugs using Chem Elut columns at 500 and 2,000 microg/L (2,000 and 8,000 microg/L for haloperidol) were in the range 21-65%, with intra-assay and inter-assay precisions of less than 17% and 19%, respectively. Limits of detection (LODs) and limits of quantitation (LOQs) for mirtazapine, chlorpromazine, methotrimeprazine, clothiapine, olanzapine, clozapine, and thioridazine ranged from 62 to 161 microg/L and from 205 to 531 microg/L, respectively. LOD and LOQ for haloperidol were 442 and 1,458 microg/L, respectively. Recoveries of these compounds using Bond Elut Certify columns at 500 and 2,000 microg/L (2,000 and 8,000 microg/L for haloperidol) were in the range 44-97%, with intra-assay and inter-assay precisions of less than 7% and 14%, respectively. LODs and LOQs for mirtazapine, chlorpromazine, methotrimeprazine, clothiapine, olanzapine, clozapine, and thioridazine ranged from 37 to 66 microg/L and from 122 to 218 microg/L, respectively. LOD and LOQ for haloperidol were 156 and 515 microg/L, respectively. Linearity was observed in the studied range for all compounds with r(2) values of >0.999. The use of the mixed-mode bonded-silica Bond Elut Certify columns showed advantages comparing with Chem Elut columns for the screening of these psychotropic agents such as higher recoveries, cleaner extracts, better sensitivity, better precision and less solvent consumption and subsequent disposal.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16226158     DOI: 10.1016/j.forsciint.2004.12.007

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  4 in total

1.  Determination of mirtazapine in spiked human plasma and tablets by first derivative spectrofluorimetric method.

Authors:  Rasha M Youssef
Journal:  Saudi Pharm J       Date:  2010-01-06       Impact factor: 4.330

Review 2.  Does olanzapine warrant clinical pharmacokinetic monitoring in schizophrenia?

Authors:  Erin Schwenger; Jane Dumontet; Mary H H Ensom
Journal:  Clin Pharmacokinet       Date:  2011-07       Impact factor: 6.447

3.  Electrochemical studies for the determination of quetiapine fumarate and olanzapine antipsychotic drugs.

Authors:  Manal A El-Shal
Journal:  Adv Pharm Bull       Date:  2013-08-20

4.  Organ-specific bioaccumulation of PCBs and PAHs in African sharptooth catfish (Clarias gariepinus) and common carp (Cyprinus carpio) from the Hartbeespoort Dam, South Africa.

Authors:  Cornelius Rimayi; Luke Chimuka
Journal:  Environ Monit Assess       Date:  2019-10-30       Impact factor: 2.513

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.