Literature DB >> 16223714

Indoor air quality in two urban elementary schools--measurements of airborne fungi, carpet allergens, CO2, temperature, and relative humidity.

Gurumurthy Ramachandran1, John L Adgate, Sudipto Banerjee, Timothy R Church, David Jones, Ann Fredrickson, Ken Sexton.   

Abstract

This article presents measurements of biological contaminants in two elementary schools that serve inner city minority populations. One of the schools is an older building; the other is newer and was designed to minimize indoor air quality problems. Measurements were obtained for airborne fungi, carpet loadings of dust mite allergens, cockroach allergens, cat allergens, and carpet fungi. Carbon dioxide concentrations, temperature, and relative humidity were also measured. Each of these measurements was made in five classrooms in each school over three seasons--fall, winter, and spring. We compared the indoor environments at the two schools and examined the variability in measured parameters between and within schools and across seasons. A fixed-effects, nested analysis was performed to determine the effect of school, season, and room-within-school, as well as CO2, temperature and relative humidity. The levels of all measured parameters were comparable for the two schools. Carpet culturable fungal concentrations and cat allergen levels in the newer school started and remained higher than in the older school over the study period. Cockroach allergen levels in some areas were very high in the newer school and declined over the study period to levels lower than the older school. Dust mite allergen and culturable fungal concentrations in both schools were relatively low compared with benchmark values. The daily averages for temperature and relative humidity frequently did not meet ASHRAE guidelines in either school, which suggests that proper HVAC and general building operation and maintenance procedures are at least as important as proper design and construction for adequate indoor air quality. The results show that for fungi and cat allergens, the school environment can be an important exposure source for children.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16223714     DOI: 10.1080/15459620500324453

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  12 in total

1.  The impact of school building conditions on student absenteeism in Upstate New York.

Authors:  Elinor Simons; Syni-An Hwang; Edward F Fitzgerald; Christine Kielb; Shao Lin
Journal:  Am J Public Health       Date:  2010-07-15       Impact factor: 9.308

Review 2.  The effect of environmental parameters on the survival of airborne infectious agents.

Authors:  Julian W Tang
Journal:  J R Soc Interface       Date:  2009-09-22       Impact factor: 4.118

3.  A side-by-side comparison of three allergen sampling methods in settled house dust.

Authors:  Megan Sandel; Johnna S Murphy; Sherry L Dixon; John L Adgate; Ginger L Chew; Samuel Dorevitch; David E Jacobs
Journal:  J Expo Sci Environ Epidemiol       Date:  2014-05-07       Impact factor: 5.563

Review 4.  Pest and allergen exposure and abatement in inner-city asthma: a work group report of the American Academy of Allergy, Asthma & Immunology Indoor Allergy/Air Pollution Committee.

Authors:  William J Sheehan; Pitud A Rangsithienchai; Robert A Wood; Don Rivard; Sasawan Chinratanapisit; Matthew S Perzanowski; Ginger L Chew; James M Seltzer; Elizabeth C Matsui; Wanda Phipatanakul
Journal:  J Allergy Clin Immunol       Date:  2010-03       Impact factor: 10.793

5.  The effects of building-related factors on classroom relative humidity among North Carolina schools participating in the 'Free to Breathe, Free to Teach' study.

Authors:  K A Angelon-Gaetz; D B Richardson; D M Lipton; S W Marshall; B Lamb; T LoFrese
Journal:  Indoor Air       Date:  2015-01-03       Impact factor: 5.770

6.  Indoor Air Quality Assessment Using a CO2 Monitoring System Based on Internet of Things.

Authors:  Gonçalo Marques; Cristina Roque Ferreira; Rui Pitarma
Journal:  J Med Syst       Date:  2019-02-07       Impact factor: 4.460

Review 7.  Indoor allergens in school and day care environments.

Authors:  Päivi M Salo; Michelle L Sever; Darryl C Zeldin
Journal:  J Allergy Clin Immunol       Date:  2009-07-03       Impact factor: 10.793

8.  The Relative Performance of NDIR-based Sensors in the Near Real-time Analysis of CO₂ in Air.

Authors:  Sudhir Kumar Pandey; Ki-Hyun Kim
Journal:  Sensors (Basel)       Date:  2007-09-03       Impact factor: 3.576

9.  Indoor and outdoor monitoring of volatile organic compounds in school buildings: indicators based on health risk assessment to single out critical issues.

Authors:  Gianluigi de Gennaro; Genoveffa Farella; Annalisa Marzocca; Antonio Mazzone; Maria Tutino
Journal:  Int J Environ Res Public Health       Date:  2013-11-25       Impact factor: 3.390

10.  Influence of meteorological factors on the level and characteristics of culturable bacteria in the air in Gliwice, Upper Silesia (Poland).

Authors:  Ewa Brągoszewska; Józef S Pastuszka
Journal:  Aerobiologia (Bologna)       Date:  2018-03-01       Impact factor: 2.410

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.