Literature DB >> 16223613

Contrast-enhanced MR angiography (CE-MRA) in the evaluation of vascular complications of renal transplantation.

R Jain1, S Sawhney.   

Abstract

Vascular complications associated with renal transplantation merit urgent investigation since they are often correctable, and timely intervention can help salvage the graft kidney. Contrast-enhanced MR angiography (CE-MRA) is a promising non-invasive technique, uses relatively non-nephrotoxic contrast agents and can rapidly demonstrate the underlying lesion in most instances. In this pictorial review we present the spectrum of abnormalities, as well as the pitfalls of interpretation of CE-MRA, that we encountered in 41 cases where there was clinical suspicion of vascular complications of renal transplantation. We believe that CE-MRA is a valuable, non-invasive screening technique in these cases, and further investigation and management of these patients can be confidently tailored to the results of the CE-MRA study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16223613     DOI: 10.1016/j.crad.2005.05.004

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  7 in total

Review 1.  How have the past 5 years of research changed clinical practice in paediatric nephrology?

Authors:  Stephen D Marks
Journal:  Arch Dis Child       Date:  2007-04       Impact factor: 3.791

2.  Allograft dysfunction and parenchymal necrosis associated with renal artery stenosis and perigraft hematoma after kidney transplantation.

Authors:  Han Sae Kim; Jin Ho Lee; Dong Yeol Lee; Hee Yeoun Kim; Dong Han Kim; Joon Seok Oh; Yong Hun Sin; Joong Kyung Kim; Seun Deuk Hwang
Journal:  Korean J Transplant       Date:  2020-06-30

Review 3.  Magnetic resonance imaging in the complications of kidney transplantation.

Authors:  M Onniboni; M De Filippo; R Averna; L Coco; M Zompatori; N Sverzellati; C Rossi
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

4.  Motion corrected cadence CPS ultrasound for quantifying response to vasoactive drugs in a rat kidney model.

Authors:  Rachel E Pollard; Paul A Dayton; Katherine D Watson; Xiaowen Hu; Ismayil M Guracar; Katherine W Ferrara
Journal:  Urology       Date:  2009-07-09       Impact factor: 2.649

Review 5.  Transplant renal artery stenosis: clinical manifestations, diagnosis and therapy.

Authors:  Wei Chen; Liise K Kayler; Martin S Zand; Renu Muttana; Victoria Chernyak; Graciela O DeBoccardo
Journal:  Clin Kidney J       Date:  2014-12-09

6.  Size and PEG Length-Controlled PEGylated Monocrystalline Superparamagnetic Iron Oxide Nanocomposite for MRI Contrast Agent.

Authors:  Li-Hua Deng; Hai Jiang; Fu-Lin Lu; Han-Wei Wang; Yu Pu; Chang-Qiang Wu; Hong-Jie Tang; Ye Xu; Tian-Wu Chen; Jiang Zhu; Cheng-Yi Shen; Xiao-Ming Zhang
Journal:  Int J Nanomedicine       Date:  2021-01-08

7.  Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

Authors:  Eric M Bultman; Jessica Klaers; Kevin M Johnson; Christopher J François; Mark L Schiebler; Scott B Reeder; Walter F Block
Journal:  Magn Reson Imaging       Date:  2013-10-15       Impact factor: 3.130

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.