Literature DB >> 16222376

Raman line mapping as a fast method for analyzing pharmaceutical bead formulations.

Slobodan Sasić1, Donald A Clark, John C Mitchell, Martin J Snowden.   

Abstract

This paper describes the use of principal component analysis (PCA) to de-noise Raman spectra and considerably shorten data acquisition time in Raman mapping experiments. A solid dosage pharmaceutical material (bead) is mapped by a Raman line-mapping system. The mapping acquisition time was varied from 30 s (usually employed in practice) to only 3 s. Apparently excessive noise in the maps measured for 3 s is removed by PCA and the maps of all three components of the bead are then binarized and compared. It is found that spatial difference is negligible despite the remarkably different acquisition times employed. The spectra acquired for 3 s and reconstructed via PCA are found to largely overlap with the spectra acquired for 30 s. The signal to noise ratio of the Raman mapping spectra does not obey the expected root t dependence, thereby preventing straightforward estimation of the shortest usable acquisition time (which is to a lesser extent also a function of the binarization threshold). The results reveal that Raman microscopy can be considered a fast method for mapping some materials, in contrast to the established opinion that it is an inherently slow technique.

Mesh:

Year:  2005        PMID: 16222376     DOI: 10.1039/b506523b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Safety and robustness of coated pellets: self-healing film properties and storage stability.

Authors:  Simon Ensslin; Klaus Peter Moll; Thomas Haefele-Racin; Karsten Mäder
Journal:  Pharm Res       Date:  2009-03-12       Impact factor: 4.200

2.  Raman mapping of low-content API pharmaceutical formulations. I. Mapping of Alprazolam in Alprazolam/Xanax tablets.

Authors:  Slobodan Sasić
Journal:  Pharm Res       Date:  2006-10-18       Impact factor: 4.580

3.  Assessment of drug content uniformity of atropine sulfate triturate by liquid chromatography-tandem mass spectrometry, X-ray powder diffraction, and Raman chemical imaging.

Authors:  Kei Moriyama; Yoichiro Takami; Natsuki Uozumi; Akiko Okuda; Mayumi Yamashita; Rie Yokomizo; Kenichi Shimada; Takashi Egawa; Takehito Kamei; Kazunobu Takayanagi
Journal:  J Pharm Health Care Sci       Date:  2016-02-10

4.  Non plasmonic semiconductor quantum SERS probe as a pathway for in vitro cancer detection.

Authors:  Rupa Haldavnekar; Krishnan Venkatakrishnan; Bo Tan
Journal:  Nat Commun       Date:  2018-08-03       Impact factor: 14.919

  4 in total