Literature DB >> 16219243

Implant stability during initiation and resolution of experimental periimplantitis: an experimental study in the dog.

Lars Sennerby1, Leif G Persson, Tord Berglundh, Ann Wennerberg, Jan Lindhe.   

Abstract

BACKGROUND: Histologic studies have demonstrated the possibility to reestablish direct bone-implant contacts after ligature-induced periimplantitis. The influence of the reosseointegration on the stability of implants is not known.
PURPOSE: The aim of the present investigation was to study bone tissue and associated implant stability alterations that occurred during induction and resolution of periimplantitis using resonance frequency analysis (RFA), radiography, and histology.
MATERIALS AND METHODS: Three implants with smooth (turned) or roughened (SLA) surfaces were placed in each side of the edentulous mandible of four dogs. Experimental periimplantitis was induced for 3 months. Five weeks later, the animals were treated with antibiotics and surgical therapy and were followed for another 6 months. Periapical radiographs and RFA were used to evaluate marginal bone levels and implant stability throughout the study period. After termination, the tissue-implant interface was evaluated by light microscopy in ground sections.
RESULTS: There was a linear relationship between radiographic and RFA findings because continuous loss of marginal bone and a decrease in implant stability were observed for both implant surfaces during the periimplantitis period. Antibiotic treatment and surgical therapy resulted in some reosseointegration, which was more marked for the SLA surface. The resonance frequency values corresponded well to the histometric measurements because reosseointegration resulted in an increase in implant stability.
CONCLUSIONS: The findings from the present study indicate a linear relationship between marginal bone level and resonance frequency value. It is suggested that the RFA technique is sensitive and may be used to detect even a minor change in the level of bone-implant contact.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16219243     DOI: 10.1111/j.1708-8208.2005.tb00057.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Re-stability of dental implants following treatment of peri-implantitis.

Authors:  Fawad Javed; Hamza Ather Hussain; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-09-16

2.  Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.

Authors:  Joelle Marie García-Morales; Pedro Tortamano-Neto; Francisco Fernando Todescan; José Carlos Silva de Andrade; Juliana Marotti; Denise Maria Zezell
Journal:  Lasers Med Sci       Date:  2011-07-06       Impact factor: 3.161

Review 3.  Animal models for periodontal regeneration and peri-implant responses.

Authors:  Alpdogan Kantarci; Hatice Hasturk; Thomas E Van Dyke
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

4.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

5.  The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia.

Authors:  In-Phill Park; Seong-Kyun Kim; Shin-Jae Lee; Joo-Hee Lee
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

6.  Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs.

Authors:  Manuel M Romero-Ruiz; Francisco Javier Gil-Mur; José Vicente Ríos-Santos; Pedro Lázaro-Calvo; Blanca Ríos-Carrasco; Mariano Herrero-Climent
Journal:  Int J Mol Sci       Date:  2019-05-09       Impact factor: 5.923

7.  Combination Use of BMP2 and VEGF165 Promotes Osseointegration and Stability of Titanium Implants in Irradiated Bone.

Authors:  Bo Huang; Qianqian Yao; Yan Huang; Liang Zhang; Yang Yao; Ping Gong; Hua Tang
Journal:  Biomed Res Int       Date:  2018-11-29       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.