Literature DB >> 16219050

Indices for assessment of hemodialysis adequacy: a comparison of different formulae.

Fatiu Arogundade1, Rashad S Barsoum.   

Abstract

Of the various indices used in the assessment of dialysis adequacy, fractional urea clearance controlled for volume of distribution "Kt/V" remains the most widely used. Its determination is best performed by formal urea kinetic modeling (UKM), which is laborious and cumbersome, and the computational softwares are largely unavailable, particularly in developing countries. Consequently, different equations have been developed that approximate the formal UKM determination. Of the available formulae, that from second-generation logarithmic equation have been found to approximate values derived from formal UKM closely. We set out to determine the clinical utility of percent reduction of urea and Kt/V formulae derived from it, using the logarithmic equation as the standard.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16219050     DOI: 10.1111/j.1492-7535.2005.01148.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  2 in total

1.  Alterations of bone microstructure and strength in end-stage renal failure.

Authors:  A Trombetti; C Stoermann; T Chevalley; B Van Rietbergen; F R Herrmann; P-Y Martin; R Rizzoli
Journal:  Osteoporos Int       Date:  2012-10-26       Impact factor: 4.507

2.  Using the Intelligent System to Improve the Delivered Adequacy of Dialysis by Preventing Intradialytic Complications.

Authors:  Mohammad Karimi; Daryoosh Dideban; Hadi Heidari
Journal:  J Healthc Eng       Date:  2022-06-23       Impact factor: 3.822

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.