Literature DB >> 16217786

Fat/water separation in single acquisition steady-state free precession using multiple echo radial trajectories.

Aiming Lu1, Thomas M Grist, Walter F Block.   

Abstract

Phase detection in fully refocused SSFP imaging has recently allowed fat/water separation without preparing the magnetization or using multiple acquisitions. Instead, it exploits the phase difference between fat and water at an echo time at the midpoint of the TR. To minimize the TR for improved robustness to B0 inhomogeneity, a 3D projection acquisition collecting two half echoes at the beginning and end of each excitation was previously implemented. Since echoes are not formed at the midpoint of the TR, this method still requires two passes of k-space for fat/water separation. A new method is presented to linearly combine the half echoes to separate fat and water in a single acquisition. Separation using phase detection provides superior contrast between fat and water voxels. Results from high resolution angiography and musculoskeletal studies with improved robustness to inhomogeneity and a 50% scan time reduction compared to the two pass method are presented. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16217786     DOI: 10.1002/mrm.20715

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

Review 1.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

2.  Patient-specific 3D simulation of cyclic CSF flow at the craniocervical region.

Authors:  G Rutkowska; V Haughton; S Linge; K-A Mardal
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-19       Impact factor: 3.825

3.  Accelerating time-resolved MRA with multiecho acquisition.

Authors:  Hyun J Jeong; Christopher S Eddleman; Saurabh Shah; Nicole Seiberlich; Mark A Griswold; H Hunt Batjer; James C Carr; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

4.  Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR.

Authors:  Kevin M Johnson; Darren P Lum; Patrick A Turski; Walter F Block; Charles A Mistretta; Oliver Wieben
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

5.  Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively.

Authors:  Emeline J Ribot; Didier Wecker; Aurélien J Trotier; Benjamin Dallaudière; William Lefrançois; Eric Thiaudière; Jean-Michel Franconi; Sylvain Miraux
Journal:  PLoS One       Date:  2015-10-01       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.