Defibrillation efficacy testing: long-term follow-up and mortality.

Dominic A M J Theuns1, Tamas Szili-Torok, Luc J Jordaens.   

Abstract

AIMS: Extensive defibrillation threshold testing is no longer necessary to perform as devices have become more effective. We assessed the lowest effective defibrillation (LED) level at implantation and before hospital discharge and related this to outcome. METHODS AND
RESULTS: One hundred and twenty-seven consecutive patients with biphasic shock and active can devices were studied at intraoperative and predischarge testing. A subgroup of 67 patients had > or = 3 VF inductions at implant. Improvement was defined when LED decreased by > or = 3 J. The LED was significantly higher at implantation compared with predischarge (P < 0.001). Improvement was seen in 73/127 patients (58%). In the group with > or = 3 VF inductions, an implantation LED > 9 J was related to a lower LVEF (P < 0.01); 34/67 patients (51%) had improvement in LED. During follow-up, 18/127 patients died, four received heart transplantation. No different outcome was observed in patients with and without improvement. However, for those with > or = 3 VF inductions, an independent predictor of mortality was implantation LED > 9 J without improvement on the second test. Safety margin < 10 J was not related to mortality.
CONCLUSION: Repeated defibrillation efficacy testing before hospital discharge may confirm that a relatively high defibrillation energy is required. This is related to a higher mortality in long-term follow-up.

Entities:  

Mesh:

Year:  2005        PMID: 16216750     DOI: 10.1016/j.eupc.2005.04.005

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  8 in total

1.  [Annual Report 2011 of the German pacemaker and defibrillator register: Section pacemakers and AQUA-Institute for Applied Quality Improvement and Research in Health Care].

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-12

2.  [2010 annual report of the German pacemaker and defibrillator register: section pacemakers and AQUA-Institute for Applied Quality Improvement and Research in Health Care Ltd].

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-12

3.  [Annual Report 2012 of the German Heart pacemaker defibrillator round register: Section on pacemaker and AQUA Institute for Applied Quality Improvement and Research in Health Care GmbH].

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2014-12

4.  Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation.

Authors:  Zhongwei Cheng; Mintu Turakhia; Ronald Lo; Anurag Gupta; Paul C Zei; Henry H Hsia; Amin Al-Ahmad; Paul J Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-03-06       Impact factor: 1.900

5.  Incidence of very high defibrillation thresholds (DFT) and efficacy of subcutaneous (SQ) array insertion during implantable cardioverter defibrillator (ICD) implantation.

Authors:  Atul Verma; Alexander J Kaplan; Bradley Sarak; Richard Oosthuizen; Marianne Beardsall; Jan Higgenbottam; Zaev Wulffhart; Yaariv Khaykin
Journal:  J Interv Card Electrophysiol       Date:  2010-09-24       Impact factor: 1.900

6.  [Is the determination of the defibrillation threshold in patients with an implantable cardioverter-defibrillator still required?].

Authors:  M Licka; L Jahn; K Kelemen; F Voss; K Trappe; R Becker; O Bikou; M Hauck; M Koch; H A Katus; A Bauer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-11-13

7.  ICD implantation without intraoperative testing does not increase the rate of system modifications and does not impair defibrillation efficacy tested in follow-up.

Authors:  Dirk Bastian; Stefan Kracker; Matthias Pauschinger; Konrad Göhl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-07

8.  Critical analysis of ineffective post implantation implantable cardioverter-defibrillator-testing.

Authors:  Markus Roos; J Christoph Geller; Marc-Alexander Ohlow
Journal:  World J Cardiol       Date:  2017-02-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.