Literature DB >> 16216607

Measurement and reproducibility of magnetocardiographic filtered atrial signal in patients with paroxysmal lone atrial fibrillation and in healthy subjects.

Raija Koskinen1, Mika Lehto, Heikki Väänänen, Juha Rantonen, Liisa-Maria Voipio-Pulkki, Markku Mäkijärvi, Lasse Lehtonen, Juha Montonen, Lauri Toivonen.   

Abstract

Magnetocardiography (MCG) is a method complementary to electrocardiography (ECG). We examined recording and reproducibility of atrial depolarization signal by MCG. Multichannel MCG over anterior chest and orthogonal 3-lead ECG were recorded in 9 patients who had paroxysmal lone atrial fibrillation and in 10 healthy subjects in duplicate at least 1 week apart. Data were averaged using atrial wave template and high-pass filtered at 25, 40, and 60 Hz. Atrial signal duration with automatic detection of onset and offset and root mean square amplitudes of the last portion of atrial signal were determined. Coefficient of variation of atrial signal duration by MCG at 40 Hz was 3.3% and difference between the measurements was 3.5 milliseconds on average. The corresponding figures obtained by signal-averaged ECG (SAECG) were 6.1% and 6.9 milliseconds. Coefficient of variation for root mean square of the last 40 milliseconds of atrial signal were 16% in MCG and 17% in SAECG. Reproducibility was best at 40-Hz filter and similar in patients and healthy subjects. In conclusion, the reproducibility of atrial signal variables in MCG is adequate and somewhat better than in SAECG and equal in patients with lone atrial fibrillation and healthy subjects. Magnetocardiography seems to be a potentially valuable method to evaluate features of atrial depolarization in patient studies.

Entities:  

Mesh:

Year:  2005        PMID: 16216607     DOI: 10.1016/j.jelectrocard.2005.03.012

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  2 in total

1.  Predictive value of unshielded magnetocardiographic mapping to differentiate atrial fibrillation patients from healthy subjects.

Authors:  Gianluigi Guida; Anna Rita Sorbo; Riccardo Fenici; Donatella Brisinda
Journal:  Ann Noninvasive Electrocardiol       Date:  2018-06-27       Impact factor: 1.468

2.  High-resolution signal-averaged analysis of atrial electromagnetic characteristics in patients with paroxysmal lone atrial fibrillation.

Authors:  Raija Jurkko; Heikki Väänänen; Ville Mäntynen; Jouni Kuusisto; Markku Mäkijärvi; Lauri Toivonen
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.