Literature DB >> 16216026

Reliable atrial septostomy by stenting of the atrial septum.

Saar Danon1, Daniel S Levi, Juan C Alejos, John W Moore.   

Abstract

The aim of this report was to describe our experience with creating an interatrial communication by stenting the interatrial septum. In many forms of congenital heart disease, the presence of an appropriate interatrial shunt is critical. After the first several weeks of life, balloon atrial septostomy is not effective, and success with other methods is limited. Clinical records, echocardiograms, and catheterization data in patients who had an atrial septal stent placed between 2001 and 2004 at UCLA were reviewed. Changes in atrial pressures and systemic saturations were analyzed. Follow-up data and explant pathology were reviewed as available. Thirteen patients had stenting of the atrial septum (four restrictive, nine nonrestrictive). In patients with elevated right and left atrial pressures, there was a mean reduction of 2.4 and 7.4 mm Hg in right atrial and left atrial pressures, respectively. In patients with transposition physiology, there was a mean increase in oxygen saturation of 11.3%. Follow-up echocardiograms revealed patent stents with excellent position relative to the atrial septum. In six cases, the stents were removed during subsequent surgery and appeared endothelialized and patent. Stenting of the atrial septum is safe and effective in selected cases, allowing for a reliable, long-lasting, restrictive or nonrestrictive interatrial communication. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16216026     DOI: 10.1002/ccd.20508

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  Use of Amplatzer fenestrated atrial septal defect device in a child with familial pulmonary hypertension.

Authors:  Alain Fraisse; Philippe Chetaille; Zahid Amin; Francis Rouault; Marc Humbert
Journal:  Pediatr Cardiol       Date:  2006-11-16       Impact factor: 1.655

Review 2.  Radiographic appearance of pediatric cardiovascular transcatheter devices.

Authors:  Ryan J Williams; Daniel S Levi; John W Moore; M Ines Boechat
Journal:  Pediatr Radiol       Date:  2006-08-05

Review 3.  Balloon atrial septostomy - almost half a century after.

Authors:  Eliza Cinteza; Mario Carminati
Journal:  Maedica (Buchar)       Date:  2013-09

4.  Left atrial decompression through unidirectional left-to-right interatrial shunt for the treatment of left heart failure: first-in-man experience with the V-Wave device.

Authors:  Ignacio J Amat-Santos; Sebastien Bergeron; Mathieu Bernier; Ricardo Allende; Henrique Barbosa Ribeiro; Marina Urena; Philippe Pibarot; Stefan Verheye; Gad Keren; Menashe Yaacoby; Yaacov Nitzan; William T Abraham; Josep Rodés-Cabau
Journal:  EuroIntervention       Date:  2015-01       Impact factor: 6.534

5.  Atrial septal stenting - How I do it?

Authors:  Kothandam Sivakumar
Journal:  Ann Pediatr Cardiol       Date:  2015 Jan-Apr

6.  Radiofrequency Energy-Assisted Wire Atrial Septostomy to Easily Create a Large Atrial Septal Defect.

Authors:  Masahiro Nishibata; Masataka Kitano; Seiich Sato
Journal:  World J Pediatr Congenit Heart Surg       Date:  2021-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.