Literature DB >> 16215929

Aortic dissection in a neonate: case report and review of the literature.

Mayssoun J Mehanna1, Maurice C Haddad, Shadi N Malaeb, Khalid A Yunis.   

Abstract

We report a case of aortic dissection causing hypertension in a neonate, which occurred following iatrogenic intimal injury during umbilical arterial cannulation. The intimal flap was diagnosed by color Doppler sonography, and treated by conservative management with complete spontaneous healing of the intimal injury.

Entities:  

Mesh:

Year:  2005        PMID: 16215929     DOI: 10.1055/s-2005-872593

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  2 in total

1.  Iatrogenic neonatal type B aortic dissection: comprehensive MRI-based diagnosis and follow-up.

Authors:  Julia Geiger; M Markl; B Stiller; C Schlensak; R Arnold
Journal:  Pediatr Radiol       Date:  2011-06-15

2.  Umbilical artery catheter, aortic dissection, carotid cannulation, and pseudoaneurysm in a neonate: A tale of propagating pathology.

Authors:  Justin Wang; Thomas Semple; Carles Bautista-Rodriguez; Andreas Hoschtitzky; Nick Cheshire; Amy Chan-Dominy
Journal:  Ann Pediatr Cardiol       Date:  2019-07-19
  2 in total