Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.

Fegegta A Workie1, K Rais-Bahrami, Billie L Short.   

Abstract

Continuous monitoring by pulse oximetry is a common practice for preterm and critically ill newborns. A new generation of motion-tolerant pulse oximeters have been designed for improved clinical performance with a substantial reduction in alarm frequency. However, little is known about the differences among these new-generation pulse oximeters in the neonatal intensive care unit (NICU). The purpose of this study is to assess the clinical performance of two new-generation pulse oximeters in the NICU. Two new-generation pulse oximeters were used simultaneously to monitor 36 patients in the NICU. The two devices studied were the Philips FAST and the Masimo SET. Patients were randomly assigned for their digit selection and data were collected only when waveforms were of good quality and/or the pulse oximeter's pulse rate (PR) correlated with the electrocardiogram heart rate (HR). The data for oxygen saturation measurements, number of true and false alarms, and number of dropouts as well as the duration of dropouts for each pulse oximeter were recorded by the primary investigator at 5-minute intervals for a period of 2 hours on each patient. Dropouts are instances when the pulse oximeter alarm sounds due to its inability to identify the arterial pulse and provide an oxygen saturation reading. The mean gestational age for the study group was 32 weeks (rang, 24 to 42 weeks). Repeated-measures analysis of variance indicated no difference between the two devices across all time measurements (p=0.357). In addition, paired t-tests for true alarms and false alarms were not significant, with p-values of 0.151 and 0.869, respectively. There was a difference in the number of data dropouts (p<0.001): the Philips device had a nearly six-fold increase in the number of dropouts (Philips 247 versus Masimo 38). The duration of dropouts was also significant; the Philips device had three times longer duration of dropouts. Physiologic monitoring in the critical care setting requires accurate data measurements. The two new-generation pulse oximeters, the Philips FAST and Masimo SET, are equally sensitive in their ability to identify true and false alarms. Masimo pulse oximeter with its signal extraction technology, however, provides more consistent and accurate reporting of SpO2 values as demonstrated by its markedly decreased incidence of data dropouts. The Masimo unit appears to be more resistant to the effects of motion artifact.

Entities:  

Mesh:

Year:  2005        PMID: 16215921     DOI: 10.1055/s-2005-872704

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  7 in total

1.  Perfusion Index in Very Low Birth Weight Premature Infants During Their First 2 Weeks of Life.

Authors:  Robin B Knobel-Dail; David T Tanaka; Diane Holditch-Davis; John White
Journal:  Biol Res Nurs       Date:  2016-07-26       Impact factor: 2.522

2.  A pilot study to examine maturation of body temperature control in preterm infants.

Authors:  Robin B Knobel; Janet Levy; Laurence Katz; Bob Guenther; Diane Holditch-Davis
Journal:  J Obstet Gynecol Neonatal Nurs       Date:  2013-09-04

Review 3.  High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis.

Authors:  Minghua L Chen; Lei Guo; Lois E H Smith; Christiane E L Dammann; Olaf Dammann
Journal:  Pediatrics       Date:  2010-05-24       Impact factor: 7.124

4.  A physiologic reduced oxygen protocol decreases the incidence of threshold retinopathy of prematurity.

Authors:  Kenneth W Wright; David Sami; Lisa Thompson; Rangasamy Ramanathan; Roy Joseph; Sonal Farzavandi
Journal:  Trans Am Ophthalmol Soc       Date:  2006

5.  Avoiding hyperoxemia during neonatal resuscitation: time to response of different SpO2 monitors.

Authors:  Hernando Baquero; Ramiro Alviz; Armando Castillo; Fredy Neira; Augusto Sola
Journal:  Acta Paediatr       Date:  2011-01-17       Impact factor: 2.299

6.  Utility and feasibility of integrating pulse oximetry into the routine assessment of young infants at primary care clinics in Karachi, Pakistan: a cross-sectional study.

Authors:  Connor A Emdin; Fatima Mir; Shazia Sultana; A M Kazi; Anita K M Zaidi; Michelle C Dimitris; Daniel E Roth
Journal:  BMC Pediatr       Date:  2015-09-30       Impact factor: 2.125

Review 7.  Safe oxygen saturation targeting and monitoring in preterm infants: can we avoid hypoxia and hyperoxia?

Authors:  Augusto Sola; Sergio G Golombek; María Teresa Montes Bueno; Lourdes Lemus-Varela; Claudia Zuluaga; Fernando Domínguez; Hernando Baquero; Alejandro E Young Sarmiento; Diego Natta; Jose M Rodriguez Perez; Richard Deulofeut; Ana Quiroga; Gabriel Lara Flores; Mónica Morgues; Alfredo García-Alix Pérez; Bart Van Overmeire; Frank van Bel
Journal:  Acta Paediatr       Date:  2014-07-28       Impact factor: 2.299

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.