Literature DB >> 16213250

Reliability of traditional and fractal dimension measures of quiet stance center of pressure in young, healthy people.

Tim L Doyle1, Robert U Newton, Angus F Burnett.   

Abstract

OBJECTIVES: To assess reliability of traditional and fractal dimension measures of quiet stance center of pressure (COP).
DESIGN: Cross-sectional study.
SETTING: University laboratory. PARTICIPANTS: Thirty young healthy men (n=20) and women (n=10) (mean age, 23 y).
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: COP was recorded for 3 trials across 4 conditions: eyes open and eyes closed standing on firm and foam surfaces. Traditional COP variables--peak sway velocity and range of sway, both in the anteroposterior (AP) and mediolateral (ML) directions, and total excursion area, and fractal dimension of the COP in the AP and ML directions--were calculated. Reliability statistics were calculated.
RESULTS: Range of sway (AP) was the most reliable traditional variable (intraclass correlation coefficient model 2,1 [ICC(2,1)] range -.28 to .72.). Peak sway velocity (AP) had poorest reliability (ICC(2,1) range, .05-.29). Only 1 of the traditional variables had excellent reliability; total excursion area (firm, eyes closed) (ICC(2,1)=.95). All bar 1 fractal dimension measures had excellent ICCs. Relative technical error of measurement ranged from 4% to 7% for the fractal dimension measures. Coefficients of variation were also very good, ranging from 1.8% to 6.7%.
CONCLUSIONS: Fractal dimension measures were more reliable than traditional measures of COP. Although traditional measures are used extensively to assess COP, their reliability is questionable. Fractal dimension measures show promise to reliably quantify COP and warrant further investigation.

Entities:  

Mesh:

Year:  2005        PMID: 16213250     DOI: 10.1016/j.apmr.2005.05.014

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  29 in total

1.  Reliability of center of pressure measures for assessing the development of sitting postural control in infants with or at risk of cerebral palsy.

Authors:  Anastasia Kyvelidou; Regina T Harbourne; Valerie K Shostrom; Nicholas Stergiou
Journal:  Arch Phys Med Rehabil       Date:  2010-10       Impact factor: 3.966

2.  Nonlinear analysis of posturographic data.

Authors:  Luigi Ladislao; Sandro Fioretti
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  Bimanual load carriage alters sway patterns and step width.

Authors:  Sidney T Baudendistel; Terry L Grindstaff; Adam B Rosen; Jennifer M Yentes
Journal:  Appl Ergon       Date:  2020-01-10       Impact factor: 3.661

4.  Laboratory Measures of Postural Control During the Star Excursion Balance Test After Acute First-Time Lateral Ankle Sprain.

Authors:  Cailbhe Doherty; Chris M Bleakley; Jay Hertel; Brian Caulfield; John Ryan; Eamonn Delahunt
Journal:  J Athl Train       Date:  2015-03-26       Impact factor: 2.860

5.  Effects of cognitive load on the amount and temporal structure of postural sway variability in stroke survivors.

Authors:  Hajar Mehdizadeh; Kinda Khalaf; Hamed Ghomashchi; Ghorban Taghizadeh; Ismaeil Ebrahimi; Parvaneh Taghavi Azar Sharabiani; Seyed Javad Mousavi; Mohamad Parnianpour
Journal:  Exp Brain Res       Date:  2017-11-14       Impact factor: 1.972

6.  Reliability of center of pressure measures for assessing the development of sitting postural control through the stages of sitting.

Authors:  Jordan Wickstrom; Nick Stergiou; Anastasia Kyvelidou
Journal:  Gait Posture       Date:  2017-04-27       Impact factor: 2.840

7.  Reliability of center of pressure measures for assessing the development of sitting postural control.

Authors:  Anastasia Kyvelidou; Regina T Harbourne; Wayne A Stuberg; Junfeng Sun; Nicholas Stergiou
Journal:  Arch Phys Med Rehabil       Date:  2009-07       Impact factor: 3.966

8.  [Reliability of static posturography in elderly persons].

Authors:  C M Bauer; I Gröger; R Rupprecht; C O Tibesku; K G Gassmann
Journal:  Z Gerontol Geriatr       Date:  2009-07-30       Impact factor: 1.281

9.  The reliability of a portable clinical force plate used for the assessment of static postural control: repeated measures reliability study.

Authors:  Samira Golriz; Jeffrey J Hebert; K Bo Foreman; Bruce F Walker
Journal:  Chiropr Man Therap       Date:  2012-05-23

10.  Rehabilitation program for traumatic chronic cervical pain associated with unsteadiness: a single case study.

Authors:  Danik Lafond; Annick Champagne; Rosalie Cadieux; Martin Descarreaux
Journal:  Chiropr Osteopat       Date:  2008-11-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.