Literature DB >> 16209901

Effect of an unstable shoe construction on lower extremity gait characteristics.

Benno Nigg1, Sabrina Hintzen, Reed Ferber.   

Abstract

BACKGROUND: To compare kinematics, kinetics and muscle activity during standing and walking for healthy subjects using an unstable test shoe (Masai Barefoot Technology, MBT) and a stable control shoe.
METHODS: Eight subjects volunteered for this study. During quiet standing, center of pressure excursion and muscle activity were determined. During walking, lower extremity kinematics, kinetics, and muscle electromyographic (EMG) signals were determined. Data were collected for the two shoe conditions after a 2week accommodation period. Statistics included repeated measures ANOVAs (alpha = 0.05) and post hoc tests where appropriate.
FINDINGS: During quiet standing, the center of pressure excursion was significantly and substantially greater in the unstable compared to the control shoe. Electromyographic intensity increased in the unstable test shoe for all tested muscles, but only significantly for the tibialis anterior. During locomotion, kinematics were similar in the two shoe conditions except for the initial plantar-dorsiflexion, which showed a significant more dorsiflexed position during the first half of stance in the unstable test shoe compared to the stable control shoe. The angular impulses did not show any significant differences between the two shoe conditions for all three joints but some trends towards a reduction for the knee and hip joint. There were no significant differences in electromyographic activities between the control and the unstable shoe. However, several muscles showed some trends.
INTERPRETATION: The unstable shoe produced changes and trends in kinematic, kinetic and electromyographic characteristics that seemed to be advantageous for the locomotor system. Further studies should investigate muscle strength, dynamic stability, pain reduction for arthritic knees and injury prevention for high performance athletes when using the unstable shoes.

Entities:  

Mesh:

Year:  2005        PMID: 16209901     DOI: 10.1016/j.clinbiomech.2005.08.013

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  17 in total

1.  Effects of unstable shoes on energy cost during treadmill walking at various speeds.

Authors:  Keiji Koyama; Hisashi Naito; Hayao Ozaki; Toshio Yanagiya
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

Review 2.  Biomechanical and neural changes evaluation induced by prolonged use of non-stable footwear: a systematic review.

Authors:  R Papalia; G Di Pino; A Tecame; G Vadalà; D Formica; A Di Martino; E Albo; V Di Lazzaro; V Denaro
Journal:  Musculoskelet Surg       Date:  2015-04-11

3.  Comparison of ankle and subtalar joint complex range of motion during barefoot walking and walking in Masai Barefoot Technology sandals.

Authors:  Sophie Roberts; Ivan Birch; Simon Otter
Journal:  J Foot Ankle Res       Date:  2011-01-02       Impact factor: 2.303

4.  Analysis of hip joint loading during walking with different shoe types using instrumented total hip prostheses.

Authors:  Y Palmowski; S Popović; D Kosack; P Damm
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

5.  Effect of the application of a metatarsal bar on pressure in the metatarsal bones of the foot.

Authors:  Se Won Yoon
Journal:  J Phys Ther Sci       Date:  2015-07-22

6.  The effect of rollover footwear on the rollover function of walking.

Authors:  Saeed Forghany; Christopher J Nester; Barry Richards
Journal:  J Foot Ankle Res       Date:  2013-07-09       Impact factor: 2.303

7.  Post-marathon wearing of Masai Barefoot Technology shoes facilitates recovery from race-induced fatigue: an evaluation utilizing a visual analog scale.

Authors:  Kento Nakagawa; Takashi Obu; Kazuyuki Kanosue
Journal:  Open Access J Sports Med       Date:  2014-12-08

8.  Salient features of the Maasai foot: analysis of 1,096 Maasai subjects.

Authors:  Jun Young Choi; Jin Soo Suh; Lan Seo
Journal:  Clin Orthop Surg       Date:  2014-11-10

9.  Alteration of the foot center of pressure trajectory by an unstable shoe design.

Authors:  Mona Khoury; Amir Haim; Amir Herman; Nimrod Rozen; Alon Wolf
Journal:  J Foot Ankle Res       Date:  2015-12-01       Impact factor: 2.303

10.  Effect on the parameters of the high-heel shoe and transfer time of ground reaction force during level walking.

Authors:  Seung-Hyun Hyun; Young-Pyo Kim; Che-Cheong Ryew
Journal:  J Exerc Rehabil       Date:  2016-10-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.