Literature DB >> 16208908

Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography.

B Hyle Park1, Mark C Pierce, Barry Cense, Johannes F de Boer.   

Abstract

We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longer lies in the QU-plane. The optic axis orientation can be recovered as an angle on this rotated plane, subject to an offset and overall indeterminacy in sign such that only the magnitude, but not the direction, of a change in orientation can be determined. We discuss the accuracy of optic axis determination due to a fundamental limit on the accuracy with which a polarization state can be determined as a function of signal-to-noise ratio.

Entities:  

Mesh:

Year:  2005        PMID: 16208908     DOI: 10.1364/ol.30.002587

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  16 in total

1.  Henle fiber layer phase retardation measured with polarization-sensitive optical coherence tomography.

Authors:  Barry Cense; Qiang Wang; Sangyeol Lee; Liang Zhao; Ann E Elsner; Christoph K Hitzenberger; Donald T Miller
Journal:  Biomed Opt Express       Date:  2013-10-01       Impact factor: 3.732

2.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

Review 3.  Polarization sensitive optical coherence tomography - a review [Invited].

Authors:  Johannes F de Boer; Christoph K Hitzenberger; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

4.  Estimation of Jones matrix, birefringence and entropy using Cloude-Pottier decomposition in polarization-sensitive optical coherence tomography.

Authors:  Masahiro Yamanari; Satoru Tsuda; Taiki Kokubun; Yukihiro Shiga; Kazuko Omodaka; Naoko Aizawa; Yu Yokoyama; Noriko Himori; Shiho Kunimatsu-Sanuki; Kazuichi Maruyama; Hiroshi Kunikata; Toru Nakazawa
Journal:  Biomed Opt Express       Date:  2016-08-19       Impact factor: 3.732

5.  Processing-based approach for resolving the sample optic axis in endoscopic polarization-sensitive optical coherence tomography.

Authors:  David C Adams; Melissa J Suter
Journal:  Opt Express       Date:  2018-09-17       Impact factor: 3.894

6.  Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography.

Authors:  Qingyun Li; Karol Karnowski; Peter B Noble; Alvenia Cairncross; Alan James; Martin Villiger; David D Sampson
Journal:  Biomed Opt Express       Date:  2018-10-15       Impact factor: 3.732

7.  Numerical compensation of system polarization mode dispersion in polarization-sensitive optical coherence tomography.

Authors:  Ellen Ziyi Zhang; Wang-Yuhl Oh; Martin L Villiger; Liang Chen; Brett E Bouma; Benjamin J Vakoc
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

8.  Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics.

Authors:  Barry Cense; Weihua Gao; Jeffrey M Brown; Steven M Jones; Ravi S Jonnal; Mircea Mujat; B Hyle Park; Johannes F de Boer; Donald T Miller
Journal:  Opt Express       Date:  2009-11-23       Impact factor: 3.894

9.  Degradation in the degree of polarization in human retinal nerve fiber layer.

Authors:  Biwei Yin; Bingqing Wang; Henry G Rylander; Thomas E Milner
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

10.  Measuring polarization changes in the human outer retina with polarization-sensitive optical coherence tomography.

Authors:  Barry Cense; Donald T Miller; Brett J King; Thomas Theelen; Ann E Elsner
Journal:  J Biophotonics       Date:  2018-02-26       Impact factor: 3.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.