Literature DB >> 16208699

Percutaneous closure of perimembranous ventricular septal defect associated with a ventricular septal aneurysm using the Amplatzer ductal occluder.

Christopher A Tan1, Daniel S Levi, John W Moore.   

Abstract

Amplatzer ductal occluders were used for percutaneous closure of perimembranous ventricular septal defects with associated ventricular septal aneurysm in three patients. The device was well positioned and the ventricular left-to-right shunt was significantly decreased in all three patients. The procedure was tolerated well without complications in each case. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16208699     DOI: 10.1002/ccd.20499

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  8 in total

Review 1.  Radiographic appearance of pediatric cardiovascular transcatheter devices.

Authors:  Ryan J Williams; Daniel S Levi; John W Moore; M Ines Boechat
Journal:  Pediatr Radiol       Date:  2006-08-05

2.  Use of the Amplatzer muscular ventricular septal defect occluder for closure of perimembranous ventricular septal defects.

Authors:  M Szkutnik; S A Qureshi; J Kusa; E Rosenthal; J Bialkowski
Journal:  Heart       Date:  2006-09-15       Impact factor: 5.994

3.  Closure of a large perimembranous ventricular septal defect in a 4.8 kg baby with Down syndrome using a duct occluder.

Authors:  Mohammed H Alghamdi; M O Galal; Fahad Al-Habshan; Mansour Al-Mutairi
Journal:  J Saudi Heart Assoc       Date:  2014-01-26

4.  Perimembranous Ventricular Septal Defect Device Closure: Choosing Between Amplatzer Duct Occluder I and II.

Authors:  Amal El-Sisi; R Sobhy; V Jaccoub; H Hamza
Journal:  Pediatr Cardiol       Date:  2017-03-01       Impact factor: 1.655

5.  Multiple transcatheter interventions in the same session in congenital cardiopathies.

Authors:  Saritas Turkay; Erdem Abdullah; Akdeniz Celal; Zeybek Cenap; Erol Nurdan; Demir Fadli; Demir Halil; Aydemir Numan Ali; Celebi Ahmet
Journal:  J Cardiovasc Dis Res       Date:  2010-10

6.  Percutaneous closure of ventricular septal defect associated with tunnel-shaped aneurysm using the Amplatzer duct occluder.

Authors:  Muhammad Dilawar; Mohammed Numan; Amal El-Sisi; Salwa Morcos Gendi; Zaheer Ahmad
Journal:  Pediatr Cardiol       Date:  2007-10-20       Impact factor: 1.655

7.  Safety of an improved patent ductus arteriosus occluder for transcatheter closure of perimembranous ventricular septal defects with abnormally attached tricuspid chordae tendineae.

Authors:  Lu He; Ya-Juan Du; Ge-Sheng Cheng; Yu-Shun Zhang
Journal:  World J Clin Cases       Date:  2019-03-06       Impact factor: 1.337

8.  Transcatheter Device Closure of Perimembranous Ventricular Septal Defect in Pediatric Patients: Long-Term Outcomes.

Authors:  Jayal Hasmukhbhai Shah; Sanket Pravinchandra Saraiya; Tushar Sudhakarrao Nikam; Mukesh Jitendra Jha
Journal:  Heart Views       Date:  2020-01-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.