Literature DB >> 16207142

Evaluation of the ABX Pentra 400: a newly available clinical chemistry analyser.

Pascal Coudène1, Benjamin Marson, Stéphanie Badiou, Sébastien Flavier, Sébastien Anelli, Jean Paul Cristol, Anne Marie Dupuy.   

Abstract

The performance of the ABX Pentra 400, a new multiparametric analyser available for routine and specialised clinical chemistry analyses, was evaluated according to the National Committee for Clinical Laboratory Standards (NCCLS) and Valtec protocols. Substrate concentrations and enzyme activities were determined by spectrophotometric measurement after coloured reaction or UV detection-based reactions; electrolyte concentrations were determined with ion-selective electrodes, and specific protein concentrations were assayed by immunoturbidimetry. In total, 32 of the most common clinical chemistry parameters were evaluated under simulated routine conditions. The analytical performance of the system and the quality of the ABX Pentra reagent line were both examined in a single-site study. The ABX Pentra 400 was compared with the Olympus AU640, Konelab-Konepro, Beckman Coulter-Immage and Beckman Coulter-Access 2, depending on the tests available on these analysers. The coefficient of variation (CV) values were within expected values. Coefficients of correlation showed high correlation between the analysers compared. The influence of interfering substances was moderate. The practicability of the system was good. We conclude that good reliability and practicability make the ABX Pentra 400 system suitable for laboratories with various needs.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16207142     DOI: 10.1515/CCLM.2005.133

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Evaluation of imprecision, bias and total error of clinical chemistry analysers.

Authors:  S S Biswas; M Bindra; V Jain; P Gokhale
Journal:  Indian J Clin Biochem       Date:  2014-06-22

2.  Chronic kidney disease and associated factors among adult population in Southwest Ethiopia.

Authors:  Kindie Mitiku Kebede; Dejene Derseh Abateneh; Melkamu Beyene Teferi; Abyot Asres
Journal:  PLoS One       Date:  2022-03-03       Impact factor: 3.240

3.  The Roche Total Mycophenolic Acid® assay: An application protocol for the ABX Pentra 400 analyzer and comparison with LC-MS in children with idiopathic nephrotic syndrome.

Authors:  François Parant; Bruno Ranchin; Marie-Claude Gagnieu
Journal:  Pract Lab Med       Date:  2017-01-04

4.  Co-Administration of Iron and Bioavailable Curcumin Reduces Levels of Systemic Markers of Inflammation and Oxidative Stress in a Placebo-Controlled Randomised Study.

Authors:  Helena Tiekou Lorinczova; Gulshanara Begum; Lina Temouri; Derek Renshaw; Mohammed Gulrez Zariwala
Journal:  Nutrients       Date:  2022-02-08       Impact factor: 5.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.